SMS Status Messages:
HEATER
ON 30min
-
heater status and time until switching off
GSM (0-31): 28
-
GSM receive signal level (not less than 10)
Voltage: 12.8
V
-
car-system voltage
Temp
heater
:
5
0С
-
heater's temperature sensor's value
Temp
sensor
:
1
0С
-
car interior's temperature sensor's value
Flame: no
- heater's flame sensor's value
Output
:
off
-
auxiliary output OUT status
GPS
:
15,0
-
number of satellites and HDOP parameter
Speed
:
0km/h
-
current speed
http://google.com/maps
-
link to the current location in Google Maps
Note
:
if relevant data is not available, the fields will not be filled in
Specifications
1 4
2 5
3 6
LED
Installing a Button to Switch on the Module
Make a
Ø8
mm
hole in the plug or in another easily accessible for a driver
place. The button is connected in accordance with the color of the main
connector wires (key: Input IN - GND, LED: output AN - resistor - GND).
Note:
if a non-latching button (FIXKEY1 setting) is used to switch heater
o
n
heater will not be switched off
automatically
after time specified in TIME1
.
Installng a Car Interior Temperature Sensor
Install the sensor as far as possible from heating sources. The sensor is
connected in accordance with the colors of key connector's wires
.
General Information
Dear buyers of ALTOX equipment!
We thank you for purchasing a new ALTOX EBUS-5 GPS device. This device
will provide you with great options to control your autonomous starting
parking heater.
You need a SIM card for your ALTOX device. It is recommended to use
special plans for M2M equipment.
Use
Using ALTOX system you can control your starting parking heater remotely
using a phone. ALTOX EBUS-5 GPS device is equipped with in-built GPS-
GLONASS module which allows controlling the vehicle's location via a text
message (SMS), ALTOX HEATER mobile Internet app and via ALTOX SERVER
2.0 monitoring system in the real-time mode (TRACKING1 setting).
Control and Programming
You can start using your ALTOX module right after you have saved
authorized phone numbers in settings (3 cells: NUM1 / NUM2 / NUM3).
Saving of the first caller's phone number into cell NUM1 follows up
automatically (cell NUM1 should be empty).
To save other phone numbers use a text message
command
NUMX:+YYYYY,
where X is a number from 1 to 3, and +YYYYY is a phone number.
To clear the cell send NUMX instruction without specifying a phone number.
There are the following control options:
- Outgoing voice call and DTMF commands;
- Outgoing text messages (SMS instructions);
- Mobile applications Thermo Call, HeaterRC or others;
- Direct control via a button in the car's interior;
- Via web interface of the mobile Internet app http://
altox.
ru
/
app
Control via an outgoing call
Call the phone number of the SIM card installed in the GSM module. The
phone number you are using to make a call should already be saved in the
device (see text messages
SMS-commands
). If the call is made using a
number that has not been saved in the ALTOX module, the connection with
the device will end without receiving a response signal. The working status
of the heater will not change.
When setting CALL1 is activated, ALTOX responds to the call and plays
voice prompts (option).
If this setting is not active (CALL0), the call is dropped after a certain
number of ringing tones. 1 ringing tone - the heater switches on,
2 ringing tones - the heater switches off.
Parameter
Value
Power Supply Voltage
10
V
- 28
V
Standby Current
less than 30mA
Max Current for Auxiliary Output Terminals
15
0
mA
Operating Temperature
from
-40
to
+80°С
1 - Red - Power 12V (via fuse 1А)
2 - Blue - EBUS
3 - Black - GND (General)
4 - Green - Input IN (button and temperature sensor)
5 - White - Auxiliary output OUT (commutates at GND)
6 - Yellow - Analog output AN (commutates at +12V)
LED status
(in SIM card slot)
Solid
-
request
to SIM
,
searching for network
Blinking
1times
/2
sec
-
waiting mode
Blinking
5times/1sec
-
GPRS
/
RING
/SMS/USSD
Please deactivate PIN code request
before inserting a SIM Card!