background image

SMS Status Messages:

HEATER

 

ON 30min

    

heater status and time until switching off

GSM (0-31): 28 

  

GSM receive signal level (not less than 10)

Voltage: 12.8

V

 

  

car-system voltage

Temp

 

heater

5

0С    

heater's temperature sensor's value

Temp

 

sensor

1

0С    

car interior's temperature sensor's value

Flame: no 

  

- heater's flame sensor's value

Output

off

 

  

auxiliary output OUT status

GPS

15,0

 

  

number of satellites and HDOP parameter

Speed

0km/h

 

  

current speed

http://google.com/maps

   - 

link to the current location in Google Maps

 

Note

if relevant data is not available, the fields will not be filled in

Specifications

 

  1  4 

  2  5    

  3    6 
   

 

   

 

 

LED

Installing a Button to Switch on the Module

Make a 

Ø8

mm

 

hole in the plug or in another easily accessible for a driver 

place. The button is connected in accordance with the color of the main 
connector wires (key: Input IN - GND, LED: output AN - resistor - GND).
Note:

 

if a non-latching button (FIXKEY1 setting) is used to switch heater 

o

n

 

heater will not be switched off 

automatically 

after time specified in TIME1

.

Installng a Car Interior Temperature Sensor

Install the sensor as far as possible from heating sources. The sensor is 
connected in accordance with the colors of key connector's wires

General Information

Dear buyers of ALTOX equipment!
We thank you for purchasing a new ALTOX EBUS-5 GPS device. This device 
will provide you with great options to control your autonomous starting 
parking heater.
You need a SIM card for your ALTOX device. It is recommended to use 
special plans for M2M equipment.

Use

Using ALTOX system you can control your starting parking heater remotely 
using a phone. ALTOX EBUS-5 GPS device is equipped with in-built GPS-
GLONASS module which allows controlling the vehicle's location via a text 
message (SMS), ALTOX HEATER mobile Internet app and via ALTOX SERVER 
2.0 monitoring system in the real-time mode (TRACKING1 setting).

Control and Programming

You can start using your ALTOX module right after you have saved 
authorized phone numbers in settings (3 cells: NUM1 / NUM2 / NUM3).
Saving of the first caller's phone number into cell NUM1 follows up 
automatically (cell NUM1 should be empty).
To save other phone numbers use a text message 

command

 NUMX:+YYYYY, 

where X is a number from 1 to 3, and +YYYYY is a phone number.
To clear the cell send NUMX instruction without specifying a phone number.
There are the following control options:
- Outgoing voice call and DTMF commands;
- Outgoing text messages (SMS instructions);
- Mobile applications Thermo Call, HeaterRC or others;
- Direct control via a button in the car's interior;
- Via web interface of the mobile Internet app http://

altox.

ru

/

app

Control via an outgoing call

Call the phone number of the SIM card installed in the GSM module. The 
phone number you are using to make a call should already be saved in the 
device (see text messages 

SMS-commands

). If the call is made using a 

number that has not been saved in the ALTOX module, the connection with 
the device will end without receiving a response signal. The working status 
of the heater will not change.
When setting CALL1 is activated, ALTOX responds to the call and plays 
voice prompts (option).
If this setting is not active (CALL0), the call is dropped after a certain 
number of ringing tones. 1 ringing tone - the heater switches on, 
2 ringing tones - the heater switches off.

Parameter

Value

Power Supply Voltage

10

V

 - 28

V

Standby Current

less than 30mA

Max Current for Auxiliary Output Terminals

15

0

mA

Operating Temperature

from 

-40 

to

 +80°С

1 - Red    - Power 12V (via fuse 1А)
2 - Blue    - EBUS
3 - Black   - GND (General)
4 - Green   - Input IN (button and temperature sensor)
5 - White   - Auxiliary output OUT (commutates at GND)
6 - Yellow  - Analog output AN (commutates at +12V) 

LED status 

(in SIM card slot)

Solid 

request

 

to SIM

searching for network 

Blinking

 

1times

/2

sec

 - 

waiting mode

Blinking

 

5times/1sec 

GPRS

/

RING

/SMS/USSD

Please deactivate PIN code request 
before inserting a SIM Card!

Summary of Contents for EBUS-5 GPS

Page 1: ...re are other control units on the bus it is recommended to connect the module s control wire blue via normally open signaling relay controlled by output OUT In this case you should activate setting SEPARLINE1 that activates this relay before the data exchange In some vehicles heater s power supply might be switched off when the car is not moving In this case you might need to wake it up by sending...

Page 2: ... TRACKING1 setting Control and Programming You can start using your ALTOX module right after you have saved authorized phone numbers in settings 3 cells NUM1 NUM2 NUM3 Saving of the first caller s phone number into cell NUM1 follows up automatically cell NUM1 should be empty To save other phone numbers use a text message command NUMX YYYYY where X is a number from 1 to 3 and YYYYY is a phone number...

Page 3: ...SEOUT 0 SEPAROUT0 SEPARLINE0 KEEPOUT0 S1 w0 e1 v11 0 t99 SMSF1 SMSW0 SMSE1 SMSV 11 0 SMST99 C1 P CALL1 PASS up to 4 characters N1 N2 N3 NUM1 NUM2 NUM3 phone numbers cells B 100 10 5 1 BAL 100 BTIMER1 10 BTIMER2 5 TRANSLIT1 Text SMS with ID and Internet Settings ID 12345678901234 Unique Device Identificator S XXX X X X XXX SERVER1 XXX X X X SERVER2 XXX G apn user pass APN1 apn APN2 user APN3 pass C3...

Page 4: ... Settings LTEMP2 XX and LTEMP3 XX allow switching the heater off based on the coolant temperature or car interior s temperature sensor s data supplied with module before the operation time TIME1 XX Attention LTEMP1 2 are available not for all heater models Additional commands Command Send USSD request XXX using the module s SIM card USSD XXX Send text message ХХХ from SIM card s number to NNN SMS ...

Reviews: