background image

15

SC 710 W / SC 740 W / SC 780

DX 840 W / DX 860 / DX 900 / DX 980 / TitanPlus

GB

INSTRUCTIONS FOR DISPOSAL

At the end of the machine's
service life:
´

Remove the mains lead plug.

´

Cut through the mains lead.

´

Take the machine and the
mains lead to your local
electrical appliance recycling
collection point.

GUARANTEE

Our general terms and conditions
apply to the guarantee and
warranty.
Changes in line with technical
innovation reserved.

TECHNICAL DATA

DX 840 W

DX 860

DX 900

DX 980

TitanPlus

Working pressure

bar

100-25

170-25

190-25

200-25

180-25

175-25 (JP)

180-25 (JP,KR)

150-25 (KR)

Permissible overpressure

bar

200/32

250/32

250/32

250/32

250/32

Volumetric flow

l/h

700-400

800-400

900-400

980-400

900-400

775-400 (JP)

850-400 (JP)

850-400 (KR) 930-400 (KR)

Permissible temperature

°C

80...140

80...140

80...140

75...140

80...140

Voltage 230 V AC

E U

Voltage 220 V AC

-

Voltage 230/240 V AC

-

Voltage 200 V 3-phase AC

-

JP

JP

Voltage 220 V 3-phase AC

-

KR

KR

Voltage 230 V 3-phase AC

-

Voltage 380 V 3-phase AC

-

Voltage 400 V 3-phase AC

-

E U

E U

E U

E U

Voltage 400-415 V 3-phase AC

-

Frequency

Hz

50

50

50

50

50

60 (JP,KR)

60 (JP,KR)

Rated power

kW

3,3

5,6

6,9

7,9

6,6

Fuse

A

16

16

16

16

16

20 (JP,KR)

25 (JP,KR)

Protection class

I

I

I

I

I

Type of protection

X5

X5

X5

X5

X5

Water volume of the heater coil

l

3,5

3,5

3,5

3,5

3,5

Heating capacity

kW

62

62

62

62

62

Fuel tank capacity

l

30

30

30

30

30

Cleaning agent tank capacity

l

2x15

2x15

2x15

2x15

2x15

Permissible water inlet pressure

bar

10

10

10

10

10

Dimensions L x W x H

mm

1060x705x

1060x705x

1060x705x

1060x705x

1060x

758

758

758

758

705x758

Machine weight
(weight of trigger gun)

kg

154(5)

161(5)

173(5)

175(5)

173(5)

Sound pressure level at a
distance of 1 m from
the machine DIN 45635

dB(A)

76,8

81,4

82,6

83,7

83,2

Oil fill capacity

l

0,4

0,4

0,4

0,4

0,4

Recoil forces

N

28

41

49

54

47

Please observe the technical data on the rating plate!

Summary of Contents for Wap DX 840

Page 1: ...erhetsanvisningar 20 Vigtige sikkerhedshenvisninger 23 Tärkeitä turvallisuusohjeita 26 Pomembni varnostni predpisi 29 Va ne sigurnosne upute 32 Dôle ité bezpeènostné upozornenia 35 Dùle itá bezpeènostní upozornìní 38 Wa ne wskazówki bezpieczeñstwa 41 Fontos biztonsági útmutatások 44 Avisos de seguridad importantes 47 Avisos de segurança importantes 50 ÓçìáíôéêÝò õðïäåßîåéò áóöÜëåéáò 53 Önemli güve...

Page 2: ...upright position Important notes Do not connect the cleaner directly to the public drinking water mains observe DIN 1988 and EN 1717 A connection is permitted however briefly to a pipe interrupter with moving section with a free outlet Water may also be drawn from an open container or from a well or surface water not intended for the drin king water supply Please use suction set for this Ensure th...

Page 3: ...f this high pressure cleaner have been manufactured in accordance with 9 of the German Pressure Vessels Ordinance and successfully subjected to a pressure test OPERATION Do not damage the mains power lead e g by driving over it pulling or crushing it Remove the plug from the plug socket directly at the plug not by pulling or tearing at the mains power lead MAINTENANCE AND REPAIR CAUTION Always rem...

Page 4: ...er for persons danger of short circuit The cleaner may only be connected to a correctly installed plug socket TESTING The cleaner conforms to the Guidelines for Liquid Spray Jet Devices The high pressure cleaner must be subjected to a safety examination in accordance with the Accident Prevention Regulations for Working with Liquid Spray Jet Devices as required but at least every 12 months by an au...

Page 5: ...Center Ulm D 89287 Bellenberg Guido Oberdorfer Straße 2 8 Tel 49 07306 72 195 Fax 49 07306 3 41 29 e mail rculm wap online de GREAT BRITAIN ALTO Cleaning Systems UK Ltd Gilwilly Industrial Estate GB Penrith Cumbria CA11 9BN Tel 44 1 7 68 86 89 95 Fax 44 1 7 68 86 47 13 Telex 64309 kewg ASIA Alto Hong Kong Representative Office RM 602 Tower B Regent Ctr 70 Ta Chuen Ping Street Kwai chung HK Hong Ko...

Page 6: ...bruiksaanwijzing 23 Istruzioni sull uso 30 Driftsinstruks 37 Bruksanvisning 44 Driftsvejledning 51 Käyttöohje 58 Navodilo za uporabo 65 Uputstvo za rad 72 Prevádzkový návod 79 Provozní návod 86 Instrukcja obsługi 93 Kezelési utasítás 100 Instrucciones de manejo 107 Instruções de operação 114 Οδηγίες λειτουργίας 121 İşletme kılavuzu 128 ...

Page 7: ...tica EN 292 EN 60335 1 EN 60555 3 EN 50081 DIN EN 60335 1 E DIN VDE 0700 T 265 IEC 335 2 79 Bellenberg 01 12 1998 ATESTADO DE CONFORMIDAD DE LA UE EG VERKLARING VAN OVEREENSTEMMING Bellenberg 01 12 1998 Wap Reinigungssysteme GmbH Co Guido Oberdorfer Straße 2 8 D 89287 Bellenberg Producto Modelo Descripción La construcción de la máquina corresponde a las siguientes normas específicas Normas armoniz...

Page 8: ... lavspenningsdirektiv 73 23 EEC EF direktiv elektromagnetisk kompatibilitet 89 336 EEC EN 292 EN 60335 1 EN 60555 3 EN 50081 DIN EN 60335 1 E DIN VDE 0700 T 265 IEC 335 2 79 EF konformitetserklæring Bellenberg 01 12 1998 Wap Reinigungssysteme GmbH Co Guido Oberdorfer Straße 2 8 D 89287 Bellenberg Produkt Typ Beskrivning Apparatens konstruktion motsvarar följande tillämpliga bestämmelser Tillämpade...

Page 9: ...20 6 10 0 14 0 C C F F 70 140 212 285 M 0 R 1 5 6 0 4 3 1 R B A 0 20 60 10 0 14 0 C C F F 70 140 212 285 1 1 0 5 5 3 3 2 3 1 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 9 10 11 2 3 4 5 6 7 8 18 ...

Page 10: ...B A 20 60 100 140 C C F F 70 140 212 285 1 2 3 4 1 2 max min O I L min 2 3 4 5 6 7 8 9 10 11 12 13 SC 710 W SC 710 W SC 710 W SC 710 W SC 710 W DX DX DX DX DX R 1 5 6 0 4 3 SC SC SC SC SC ...

Page 11: ...ted 1 5 1 5 pH value in 1 solution approx 8 6 8 8 DESCRIPTION FIG 1 1 RotoFix high pressure spray lance with VarioPress trigger gun1 2 Water connection 3 Steering roller with parking brake 4 High pressure connection 5 Cleaning agent tank 6 Mains cable storage point 7 Hose storage point 8 Spray lance storage clip 9 Exhaust pipe 10 Operating panel 11 Fuel tank 12 Pressure gauge 13 Temperature contro...

Page 12: ...ed correctly by an electrician to change the direction of rotation Operate the trigger of the trigger gun several times at short intervals to bleed the system HOT WATER OPERATION Select the temperature 20 100 C Release the lock of the trigger gun and press the trigger Fig 8 Turn the operating mode switch to position When a steady jet emerges from the high pressure nozzle turn the operating mode sw...

Page 13: ...rs Change the pump oil Pump system Flame sensor Annually or every 500 operating hours Heat exchanger and ignition system Fuel system As required Grease the manual screw fittings on the spray lance and high pressure hose Descale the system OIL LEVEL CHECK OIL CHANGE Check the oil level in the high pressure pump regularly at the dipstick of the oil filler plug Top up with oil when required If the oi...

Page 14: ...into the scale remover bottle and setting the mete ring valve to maximum concentration Hold the spray lance in a separate container to collect the discharged liquid Switch on the high pressure pump Actuate the trigger gun Wap scale remover is drawn in and emerges from the spray lance foaming vigorously after approx 1 minute Switch off the high pressure pump and allow the scale remover to work for ...

Page 15: ...gh pressure pump drawing in air Suction or pressure valve of high pressure pump soiled or defective Cleaning agent tank empty Sludge in cleaning agent tank Suction valve at cleaning agent inlet soiled Have electrical connection checked Have plug socket connected correctly by an electrician to change the direction of rotation Have power supply checked by an electrician Clean or replace clogged high...

Page 16: ...age 400 415 V 3 phase AC AU Frequency Hz 50 50 50 60 TW PH KR 60 JP Rated power kW 2 7 3 6 4 5 3 3 TW PH KR Fuse A 16 16 16 15 TW PH KR Protection class I I I Type of protection X5 X5 X5 Water volume of the heater coil l 2 65 2 65 2 65 Heating capacity kW 42 42 42 Fuel tank capacity l 11 5 11 5 11 5 Cleaning agent tank capacity l 5 5 5 5 5 5 Permissible water inlet pressure bar 10 10 10 Dimensions...

Page 17: ...ltage 220 V AC Voltage 230 240 V AC Voltage 200 V 3 phase AC JP JP Voltage 220 V 3 phase AC KR KR Voltage 230 V 3 phase AC Voltage 380 V 3 phase AC Voltage 400 V 3 phase AC EU EU EU EU Voltage 400 415 V 3 phase AC Frequency Hz 50 50 50 50 50 60 JP KR 60 JP KR Rated power kW 3 3 5 6 6 9 7 9 6 6 Fuse A 16 16 16 16 16 20 JP KR 25 JP KR Protection class I I I I I Type of protection X5 X5 X5 X5 X5 Wate...

Page 18: ...Center Ulm D 89287 Bellenberg Guido Oberdorfer Straße 2 8 Tel 49 07306 72 195 Fax 49 07306 3 41 29 e mail rculm wap online de GREAT BRITAIN ALTO Cleaning Systems UK Ltd Gilwilly Industrial Estate GB Penrith Cumbria CA11 9BN Tel 44 1 7 68 86 89 95 Fax 44 1 7 68 86 47 13 Telex 64309 kewg ASIA Alto Hong Kong Representative Office RM 602 Tower B Regent Ctr 70 Ta Chuen Ping Street Kwai chung HK Hong Ko...