Alto heat pumps are supplied with 1.5" BSP parallel threads, male.  We
strongly recommend a 1.5" female socket union is applied to
inlet/outlets for future draining and servicing of the appliance.

Alto heat pumps must be installed in the return line after the filter.  If an
existing heater or back-up heater has been installed then the heat pump
should be installed between the filter and the other heater. If solar
heating has been installed, the heat pump should be installed after the solar heating system. See Drw.2 page7.

If the heat pump is to be installed at a lower level than the pool then isolation valves or non-return valves should be
installed.

Do not route any plumbing lines across heater inlet panels. All plumbing should be adequately supported.

Once all plumbing connections have been completed the filtration should be turned on and the systems tested for
leaks. A refrigerant/flow meter is located next to the control panel. Alto heat pumps will generally take the full flow
of the filtration pump. In some instances if there is too much flow (see page 12 re refrigerant/ flow meter) a by-pass
may be required. If there is insufficient flow an auxiliary booster pump may be required. Please contact your dealer
for advice.

Important 

- (applicable for stainless steel/copper heat exchangers) Standard unit. If your pool has an automatic

chemical dosing appliance the heat pump should be installed prior to the dosing system. See applicable drawings
(1-4) on pages 7-8

.

2 x1.5” Female/Threaded

Socket Unions Required

FLOW SWITCH (Optional)

Alto heat pumps have the option of installing a flow switch. A flow switch will deactivate the heater if there is a loss
of water flow i.e. in the event that the circulation pump deprimes (no flow) the heater
will switch off.

We recommend that the heat pump should be interlock wired with the
circulation pump

i.e. heat pump only functions when pool circulation pump is

running. A flow switch (provided) can also be installed 

as an extra precaution

in

the event that there is a loss of water flow (i.e. circulation pump deprimes). 

I

t is our recommendation that the flow switch is installed for added protection

on a pool installation that is 

below ground

. If the heater is to be installed on an

above ground pool, the circulation pump is normally under flooded suction
therefore, heater and filtration pump could be wired together.

In the event that there is no flow ‘E3’ will be displayed on the control panel and
heater will stop functioning.

ELECTRICIAN NOTE - PLEASE CHECK CONTINUITY OF FLOW SWITCH BEFORE INSTALLING.

PLEASE ALSO SEE PAGE 15 - FILTRATION & FAQ

OFF

ON

1 X FLOW SWITCH
1 X CRIMP -ON CONNECTIONS
1 X 1.5”- 0.75” PLN RED. BUSH
1 X 0.75” PLAIN - 0.5” FEMALE THR. RED. BUSH

Summary of Contents for AS-H40Y

Page 1: ...AS H40Y 12kW AS H50Y 15kW AS H60Y 18kW ALTOHeat Pump installation manual F1 F7 ...

Page 2: ...onnect heater to an electrical supply using a 13 amp plug When cleaning the heater unit switch off power supply Do not operate electrical switches with wet hands Repair or relocation should be carried out by a specialist contractor INDEX Page 4 Installation and Siting Page 5 Plumbing Page 9 Electrical Connection Circuit Diagram Page 10 Control Panel Functions F1 F7 Page 13 Refrigerant Flow Meter P...

Page 3: ...HEAT PUMP AS H40Y 12kW 2 ...

Page 4: ...3 HEAT PUMP AS H50Y 15kW AS H60 18kW ...

Page 5: ...ease Note the heat pump collects condensation from the evaporator fins and will continually discharge small amounts of condensate water out of the base of the unit via a drain tube Therefore it is recommended that the drain tube is directed to an area with adequate drainage Make sure that heat pump remains free of any obstructions foliage etc A minimum clearance is required around heater unit plea...

Page 6: ...applicable for stainless steel copper heat exchangers Standard unit If your pool has an automatic chemical dosing appliance the heat pump should be installed prior to the dosing system See applicable drawings 1 4 on pages 7 8 2 x1 5 Female Threaded Socket Unions Required FLOW SWITCH Optional Alto heat pumps have the option of installing a flow switch A flow switch will deactivate the heater if the...

Page 7: ...WITCH INSTALLATION GUIDE optional ANTI VIBRATION PADS AND DRAIN TUBE X 4 ANTI VIBRATION PADS PLASTIC Install on underside of heater It is recommended that Stainless Steel screws plugs are used when securing to floor Installing anti vibration feet will also help prevent corrsion to the base of the heat pump 1 X DRAIN VALVE RUBBER 1 X 2m FLEXIBLE DRAINAGE TUBE Insert drain valve into drainage hole l...

Page 8: ...lumbing layout when incorporating Solar Heating If an increased flow rate is required instal a booster pump as per drw 4 below Ball Valve BACKWASH FILTER FILTER Pool Non Return Valve Back Up Heater if required PUMP Solar Heating 3 Way Valve Install a plumbing bypass for running filtration heat pump at night Non Return Valve Position for optional Erosion Feeder Condensate Water to waste Female Thre...

Page 9: ...ystem is 3000 Litres 660 Gallons imperial per hour Ball Valve BACKWASH FILTER FILTER Pool Position for optional Erosion Feeder Non Return Valve Back Up Heater if required Condensate Water to waste PUMP Female Threaded Socket Union Ball Valve BOOSTER PUMP Solar Heating 3 Way Valve Install a plumbing bypass for running filtration heat pump at night Non Return Valve Non Return Valve Drw 3 Recommended...

Page 10: ...tage must be available at the heat pump whilst running A 40 AMP 2 Pole Contactor is required to interlock heat pump and circulation pump i e heat pump only functions when pool circulation pump is running A flow switch provided optional see page 5 can also be installed as an extra precaution in the event that there is a loss of water flow i e circulation pump deprimes NOTE PLEASE CHECK CONTINUITY O...

Page 11: ...re ie 10 H 10 C 2 On OFF button to turn heater on and off 3 The set button is used to set the F1 6 functions ie water temperature defrosting cycle and defrosting time etc see pages 11 12 PLEASE READ THE CONTROL FUNCTIONS CAREFULLY AND MAKE THE NECESSARY ADJUSTMENTS BEFORE USING YOUR HEATER CONTROL PANEL FUNCTIONS 1 3 10 40 H 2 10 ...

Page 12: ... temperature Eg If current pool water temperature is 20 C F1 has been set to 02 heating mode when the temperature reaches 20 C the heater will stop and restart when the water temperature is below 18 C When the SET button is pressed for the third time the display panel will display F3 the defrosting time The recommended setting is 5 minutes To adjust setting YOU MUST PRESS THE ON OFF BUTTON FIRST U...

Page 13: ...tandard This function is designed for saving energy EC Heat pump will stop working at an ambient temperature of 5 C and will automatically restart when the ambient temperature rises above 10 C Example When the heat pump is set in Economy mode the unit will stop working during the night when temperature drops below 5 C and will restart automatically when the temperature rises throughout the day ST ...

Page 14: ...ent water flow Prior to any adjustments make sure your filter is clean by using the backwashing and rinse procedure refer to your pool hand book for guidance Check there are no obstructions in the suction lines i e Main Drain or Skimmer s If you are unable to increase the flow rate please contact your pool dealer as you may need to increase the size of the filtration pump or there is a lack of gas...

Page 15: ...s a lack of water flow Backwash filter and check suction lines Skimmer s Main Drain s for obstruction E4 Indicates high water refrigerant pressure High limit pressure switch has activated and turned off power supply IF THE HEATER STOPS WORKING ONE OF THE FOUR ERRORS WILL BE DISPLAYED THE FAILURE LIGHT WILL BE ON AND THE RELEVANT CODE WILL START TO FLASH CONTROL PANEL FUNCTION ERROR DISPLAY 1 4 14 ...

Page 16: ...tly reduce pool heating loss The use of a solar or thermal blanket will also help extend your pool season What is the minimum ambient operating temperature The Alto Water Heat Pump will actually operate down to an ambient air temperature of 0 C but with minimal heat output Therefore we recommend that the minimum operating temperature should be 5 C Other conditions such as wind shade and physical l...

Page 17: ...g device Winterising Procedure 1 Switch off electric supply to heat pump 2 Turn off circulation pump 3 Drain water from heat pump by disconnecting pipework to and from heat pump Ensure Heat Pump is completely drained 4 Flush through water circuit in heat pump using clean tap water i e a hose into inlet connection run for 10 minutes minimum 5 Drain completely fit plastic bags secured by elastic ban...

Page 18: ... 2 All repairs replacements must be carried out by an authorised service agent appointed by Paramount Pools 3 3 This warranty extends only to the original consumer who purchased the Alto Heat Pump 3 4 The warranty terminates upon the transfer of ownership or if the heat pump is relocated save with the written permission of Paramount Pools 3 5 The warranty is only applicable to installations in Eng...

Page 19: ...uction in the skimmer Is there any obstruction in the pump basket Is the water at the correct operational level Is the filter pump working Is the filter operating pressure correct Does the filter require backwashing Have you checked the diagnostic control panel If the fault can not be diagnosed over the phone then your pool dealer will contact Paramount Pool Products UK Importer who will arrange a...

Page 20: ...xD mm 540 835 540 630 770 710 630 770 710 Gross Weight Kg 70 84 110 ALTOHeat Pumps SPECIFICATION USEFUL CONVERSIONS 1 000 British Thermal Units BTU 10 000 BTU 1 UK Horsepower 0 293 kilowatt hour 1 therm 0 7457 kilowatt Cubic Yards to Cubic Metres Cubic Metres to Cubic Yards Cubic Metres to Gallons Gallons to Cubic Metres Gallons to Litres Litres to Gallons multiply by multiply by multiply by divid...

Reviews: