background image

4

2.0 Instructions for use

Safety precautions and warnings

GB

Before starting up your high pressure washer for the first time, we advise you to read through the following
sections: 

2.0 Instructions for use and 3.0 Operating instructions and to follow all instructions to ensure the

protection of user, surroundings and machine.

2.1 Starting-up

Upon the unpacking of your machine please check it for any defects. If you find any, we kindly ask you to
contact your ALTO distributor.

Check the electric cable

The insulation of the electric cable should be quite faultless and without any cracks.
Please contact a qualified electrician or the nearest ALTO distributor if any doubts arise.

Check the voltage

Check that the voltage stated on the model tag corresponds to your mains voltage.

Power consumption, fuse

Check the power consumption stated on the model tag and then check correct prefuse.

Mains power connection

Faulty connection of the machine can cause electric shock.

l

Only connect the machine to an installation with earth connection.

l

If you are in doubt about connections, please contact a qualified electrician for correct installation.

l

We recommend you to connect the machine to a power source with a Residual Current Device (RCD),
which will disconnect the power supply if the leakage current exceeds 30 mA for 30 milli seconds.

l

The electric supply connection shall be made by a qualified electrician and comply with the latest edition
of the IEC Wiring Regulations.

Extension cable

If you want a wider radius of action ALTO highly recommend you to use an extension hose instead of an
extension cable. Where impracticable seek advice of a qualified electrician or the nearest ALTO distributor.
If you want to apply an extension cable when operating a three-phase high pressure washer, we recom-
mend you to use the cable dimensions mentioned below: 

(The use of the stated cable dimensions implies

that the mains voltage supplies a stable voltage corresponding to that stated on the model tag).

NOTE

: If an extension cable is required it must be earthed and connected through the plug to the

earth cable of your supply network in accordance with prescribed safety regulations.

l

Extension cable, plug and socket should be waterproof.

l

Always use a cable similar to the one mounted on the machine i.e. with earth connection and for outdoor
use. If you are in doubt, please contact a qualified electrician or the nearest ALTO distributor.

l

Cable connections should be kept dry and off the ground.

l

Check extension cables before usage. Don’t use damaged cables.

2.2 Operation

This machine produces a high pressure jet and operation contrary to the instructions can cause severe
injuries!
For your own and the safety of others the following precautions should always be observed:

l

WARNING! Never direct the water jet towards people, pets, electric wiring, or the
machine itself.

l

WARNING!  Never try to clean clothes or footwear on yourself or other persons.

l

We recommend you to wear goggles during operation.

l

Never work barefoot or with sandals.

l

Operator and anyone in immediate vicinity of the site of cleaning should take action to protect himself
from being struck by debris dislodged during operation.

           I

0<I<10 Amp

10<I<16 Amp

16<I<25 Amp

25<I<32 Amp

m

mm²

mm²

mm²

mm²

0-50

1,5

1,5

2,5

4,0

51-75

1,5

2,5

2,5

4,0

76-100

1,5

2,5

4,0

6,0

Summary of Contents for 40C/CA

Page 1: ...S ALTO Danmark A S Industrikvarteret DK 9560 Hadsund Tel 45 7218 2100 Instruction manual 2 13 Betriebsanweisung 14 25 Manuel d Instructions 26 37 Gebruikershandleiding 38 49 Manual de instrucciones 50...

Page 2: ...s characterised by the attitude of ALTO towards the environment The majority of the incorporated plastic compo nents and first and foremost the cabinet is made of the environmen tally desirable polypr...

Page 3: ...0 MODEL TYPE SERIAL NO PRODU CTION YEAR CAPACITY MAX PRESSURE WORKINGPRESSURE INLET PRESSURE INLET TEMPERATURE MADEINDENMARK POWER FREQUENCY VOLTAGE PHASE POWER CUNSUMPTION RPM COS INSULATION CL MOIST...

Page 4: ...extension hose instead of an extension cable Where impracticable seek advice of a qualified electrician or the nearest ALTO distributor If you want to apply an extension cable when operating a three p...

Page 5: ...hoses nozzles and connections prescribed by ALTO l For safety reasons only use original ALTO accessories and spare parts l In icy conditions never start the cleaner until machine hoses and accessorie...

Page 6: ...3 4 Clean water inlet filter at monthly inter vals Max water pressure 10 bar Let water run through the inlet hose to remove any impurities The water supply system must supply min 900 l h If there is...

Page 7: ...ct the environ ment Flush with water after use Detergents are added under low pressure through the built in dosing system 1 placed under the cover holder for container 2 Tip the cover holder for conta...

Page 8: ...the pressure may be unsteady because of air in the pump system After a short time the air has escaped from the system and the pressure will become steady Never allow the machine to operate for more th...

Page 9: ...tart stop 40CA When the spray handle is released the machine will automatically stop after approximately 10 sec The machine can be restarted just by activating the spray handle 3 6 Transport direction...

Page 10: ...surfaces 4 3 Detergents The most efficient cleaning is reached with detergents in conjunction with the high pressure cleaning For that purpose ALTO can offer you a series of products specially develo...

Page 11: ...1 Application of detergent STEP 2 High pressure cleaning In practice the working process is laid down in accordance with the actual job but as a starting point the following working method can be des...

Page 12: ...uld be cleaned of dust and sand Before mounting spray lance or any other accessory on the spray handle the machine should be started and the quick coupling cleaned of dust and sand In periods where de...

Page 13: ...tallation corresponding to the ampere consumption of the machine at a minimum Pressure fluctuating Water supply too low Dismount water hose and check the and pulsating water volume min 15 l min NB Avo...

Page 14: ...omversorgung wieder hergestellt worden ist NB Eine nderung der elektrischen Kupplung des Ger tes ist nicht gestattet 8 0 Description de fonctionnement F La pompe haute pression le syst me hydraulique...

Page 15: ...99 M a b d c f g j i k l n m o p h 40CA Deutschland Das Schaltbild und der Schaltplan des Ger tes sind unter dem Amaturenbrett angebracht...

Page 16: ...mark Nov 2001 Ort Datum der Ausstellung Johan Ley Director of Technical Operations D claration CE de Conformit ALTO Danmark A S Industrikvarteret DK 9560 Hadsund d clare ci apr s que le produit Nettoy...