T
ROUBLESHOOTING
Vector® F Series
▪
Service Manual
▪
MN-46896
▪
Rev 01
▪
07/20
79
How to Test the Probe
Before you begin
Make sure
you have:
▪
Multimeter
▪
Container of ice water
Procedure
To test the probe, do the following.
Step
Action
1.
Set
the multimeter
a
to ohms.
2.
Insert
the probe
b
into a container of ice water.
Continued on next page
NOTE:
Stir the water with the probe to ensure an
accurate measurement.
VMC-TS-003717
a
VMC-TS-003717
b