This Alto-Shaam appliance has been 

thoroughly tested and inspected to ensure only 
the highest quality unit is provided.  Upon 
receipt, check for any possible shipping damage 
and report it at once to the delivering carrier.  
See Transportation Damage and Claims section 
located in this manual.
 

This appliance, complete with unattached 

items and accessories, may have been delivered 
in one or more packages.  Check to ensure that all 
standard items and options have been received 
with each model as ordered.
 

Save all the information and instructions 

packed with the appliance.  Complete and return 
the warranty card to the factory as soon as 
possible to ensure prompt service in the event of a 
warranty parts and labor claim.  
 

This manual must be read and understood 

by all people using or installing the equipment 
model.  Contact the Alto-Shaam Tech Team Service 
Department if you have any questions concerning 
installation, operation, or maintenance.

NOte:

  All claims for warranty must include the 

full model number and serial number of 
the unit.

u N P A C K i N G

1.  Carefully remove the 

appliance from the 
carton or crate.

 

NOte:  

 Do not discard the 
carton and other 
packaging material 
until you have 
inspected the unit 
for hidden damage 
and tested it for 
proper operation.

2.  Read all instructions in this manual carefully 

before initiating the installation of this appliance.

  DO NOT DISCARD THIS MANUAL.  

This manual is considered to be part of the 
appliance and is to be provided to the owner 
or manager of the business or to the person 
responsible for training operators.  Additional 
manuals are available from the Alto-Shaam 
Tech Team Service Department.

3.  Remove all protective plastic film, packaging 

materials, and accessories from the appliance 
before connecting electrical power.  Store any 
accessories in a convenient place for future use.

®

®

Summary of Contents for ITM2-48/CT

Page 1: ...00 558 8744 USA CANADA FAX 262 251 7067 800 329 8744 U S A ONLY www alto shaam com MN 28602 10 10 p r i n t e d i n u s a I s l a n d T a k e o u t Merchandiser Models ITM2 48 STD ITM2 48 DLX ITM2 48...

Page 2: ...Procedures 7 General Holding Guidelines 8 Care and Cleaning Cleaning and Preventative Maintenance 9 Protecting Stainless Steel Surfaces 9 Cleaning Agents 9 Cleaning Materials 9 Equipment Care 10 Clea...

Page 3: ...installing the equipment model Contact the Alto Shaam Tech Team Service Department if you have any questions concerning installation operation or maintenance NOte All claims for warranty must include...

Page 4: ...s sold or moved to another location NO te Used to notify personnel of installation operation or maintenance information that is important but not hazard related CAutiON Used to indicate the presence o...

Page 5: ...de but are not limited to thermostat calibration door adjustment leveling electrical hook up and installation of optional casters or legs LEVELING Level the appliance from side to side and front to ba...

Page 6: ...8 663mm 26 1 16 662mm 28 5 16 719mm 13 1 16 331mm TO ELEC CORD 30 13 16 782mm 7 1 8 180mm 4 1 8 104mm TO ELEC CORD 48 1219mm 14 1 2 367mm 26 1 16 662mm 28 711mm 14 356mm TO ELEC CORD 42 3 4 1086mm 19...

Page 7: ...EC CORD DROP OUT 14 1 2 367mm 26 1 8 663mm 26 1 16 662mm 28 5 16 719mm 13 1 16 331mm TO ELEC CORD 66 3 4 1695mm 19 15 16 505mm HEATED PLATE AREA 14 1 2 367mm 26 1 16 662mm 28 711mm 14 356mm TO ELEC CO...

Page 8: ...eplacement use a similar one obtained from the distributor ELECTRICAL ITM2 48 voltage phase cycle hz amps kW cord plug 120 1 60 11 0 1 32 NEMA 5 15P 15A 125V Plug 230 1 50 5 5 1 26 cord included no pl...

Page 9: ...orrect temperatures are being maintained Local health regulations may vary regarding minimum serving temperatures Proper temperature range is usually 160 F 71 C or higher User safety information This...

Page 10: ...ds however a maximum of 1 to 2 minutes must be the only time period allowed for the initial heat to be released from the product Use a metal stemmed thermometer to measure the internal temperature of...

Page 11: ...gent and wipe standing water as quickly as possible after rinsing CLeANiNG AGeNts Use non abrasive cleaning products designed for use on stainless steel surfaces Cleaning agents must be chloride free...

Page 12: ...se hydrochloric acid muriatic acid on stainless steel 4 Surfaces can be wiped with a sanitizing solution after cleaning and rinsing This solution must be approved for use on stainless steel food conta...

Page 13: ...curate method of measuring safe temperatures of both hot and cold foods is by internal product temperature A quality thermometer is an effective tool for this purpose and should be routinely used on a...

Page 14: ...0 9 37 53 34 48 5 47 38 6 17 18 53 39 7 12 8 14 32 57 27 45 16 25 59 21 56 58 1 36 35 4 11 22 42 29 46 30 28 2 52 31 50 26 23 51 49 61 24 23 51 40 41 53 44 19 60 54 3 43 13 52 55 61 service Part numbe...

Page 15: ...1 5007920 1 16 INNER TOP SPOT 5005806 1 5007446 1 17 HEAT PLATE HOLDER 1007107 1 1008256 1 HEAT GUARD CORNER BRACKET 1 1008177 4 1008177 4 HEAT GUARD CORNER BRACKET 2 1008178 4 1008178 4 HEAT GUARD MI...

Page 16: ...BLIND 44 STNLS RI 2100 108 RI 2100 108 48 LAMP RECEPTACLE 120V RP 3952 6 RP 3952 8 LAMP RECEPTACLE 230V rp 3955 6 rp 3955 8 49 3 8 16 X 1 1 2 HEX CAP SC 22553 2 SC 22553 2 50 5 16 18 X 5 8 SERR HEX HD...

Page 17: ...ITM2 INSTALLATION OPERATION SERVICE MANUAL 15...

Page 18: ...ITM2 INSTALLATION OPERATION SERVICE MANUAL 16...

Page 19: ...ITM2 INSTALLATION OPERATION SERVICE MANUAL 17...

Page 20: ...ITM2 INSTALLATION OPERATION SERVICE MANUAL 18...

Page 21: ...tional fees To be valid a warranty claim must be asserted during the applicable warranty period This warranty is not transferable THIS WARRANTY DOES NOT APPLY TO 1 Calibration 2 Replacement of light b...

Reviews: