MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual
33
Operation
Indicator Light
If the indicator light does not
illuminate, the fi lters may be missing
or not properly aligned. Check them for
proper positioning. Ventless hood and
oven will not operate unless the hood is
closed properly.
Ventless Hood Model
The Ventless Hood option is factory installed directly
on the top of the Alto-Shaam Combitherm appliance.
The hood is designed to vent clean air back into the
kitchen, fi ltering vapors and grease. A high-power fan
draws steam and fumes into the hood intake and out
the top surface exhaust vent. Fumes and vapors are
circulated through fi lters. An activated charcoal fi lter
cleans the air before venting it out the top of the hood.
Filter Door Latch
Using a coin or screwdriver,
turn to open; reverse procedure
to close and latch.
Hood and oven will not operate
unless this is closed properly.
Operation
1. Turn the ventless hood power knob ON.
2. Indicator light will illuminate.
3. Wait fi ve seconds, then press the Combitherm
appliance power ON.
Timed Latching Mechanism:
In order
to evacuate steam and grease-laden
air from the oven interior, this
mechanism prevents the operator
from fully opening the oven door for
20 seconds. Longer wait times can be
programmed into the control. The
mechanism automatically disengages
at the end of a pre-set time allowing
full door extension.
Emergency Latch Release:
This
release is to be used ONLY if the timed
latch mechanism is not working or in
the event of a power outage. Repeated
use of the emergency release may
damage the switching mechanism. The
latch is located on the right side of the
appliance, toward the back.
2
1
3