MN-29805 • Rev 10 • 06/17 • Combitherm CT Express Installation Manual
21
Installation
Mobile Equipment Restraint
Any appliance that is not furnished with a power supply
cord but includes a set of casters, stand with casters,
or a stacked configuration must be installed with a
tether. Adequate means must be provided to limit the
movement of this appliance without depending on
or transmitting stress to the electrical conduit. The
following requirements apply:
1. Casters must be a maximum height of 6" (152mm).
2. Two of the casters must be the locking type.
3. Such appliances must be installed with the use of a
flexible connector secured to the building structure.
4. Each of the stacked appliances must be installed
with the use of a flexible connector secured to the
building structure. A single wall anchor may be used.
A mounting connector for a restraining device is located
on the top right back panel of the appliance chassis or
on an appliance stand, approximately 18" (457mm) from
the floor. A flexible connector is not supplied by nor is it
available from the factory.
WARNING
RISK OF ELECTRIC SHOCK.
Appliance must be secured to building
structure. Failure to observe this precaution
may result in damage to the equipment and
severe personal injury.