Function Test Checklist
MN-29805 • Rev 11 • 07/18 • Combitherm CT Express Installation Manual 37
Wire Connections
Behind the left side panel, check and tighten all electrical connections, and
tighten all electrical screws.
Behind the left side panel, check and tighten all electrical screws.
Behind the control panel, check and tighten all connections on the control board.
Behind the control panel, check and tighten all connections on the options board.
Behind the control panel, check and tighten all connections on the interface board.
Check that the SD card is fully inserted into the interface board.
Comments:
CTX Appliance Function Test
Cycle Y1 ‑ Operation fi ll/steam injection
YES
NO
Dynamic water pressure with Y1 (treated water inlet)
MEASURE
Cycle Y2 - Operation condensate cooling valve
YES
NO
Dynamic water pressure with Y2 (untreated water inlet)
MEASURE
Cycle Y3 - Operation rinse solenoid valve
YES
NO
Dynamic water pressure with Y3 (untreated water inlet)
MEASURE
Operate hand shower
YES
NO
Dynamic water pressure with hand shower activated
MEASURE
Cycle appliance in steam mode at 212° Fahrenheit (100° Celsius) for 10 minutes.
Did the appliance perform correctly?
PASS
FAIL
Record amperage at all phases:
L1
L2
L3
During the cycle, check CTP motor rotation: 3 minutes clockwise - break - 3 minutes
counter-clockwise
PASS
FAIL
Cycle appliance in convection mode at 350° Fahrenheit (175° Celsius) for 10 minutes.
Did it perform correctly?
PASS
FAIL
Record amperage at all phases:
L1
L2
L3
Cycle appliance in combination mode at 400° Fahrenheit (205° Celsius) for 10 minutes.
Did it perform correctly?
PASS
FAIL
Record amperage at all phases:
L1
L2
L3
Check motor rotation for CTC models.
Note: Arrows on the motor housing indicate proper rotation.
PASS
FAIL
Check all lines and connections for leaks, both inside and outside of the combi appliance.
PASS
FAIL
Function Test Checklist