Part numbers and drawings are subject to change without notice .

CS-200

Summary of Contents for CS-100

Page 1: ... 558 8744 U S A CANADA FAX 262 251 7067 800 329 8744 U S A ONLY www alto shaam com Consult instructions for operation and use MN 29250 Rev 6 05 18 Printed in U S A Hot Food Holding Carving Station Models CS 100 CS 200 CS 100 with Breath Guard CS 200 with Breath Guard Installation Operation Maintenance ...

Page 2: ...ty and Service Information 3 Delivery 4 Transportation Damage and Claims 5 Unpacking 6 Safety Procedures 7 Installation 9 Electrical Connection 13 Operation 14 Cleaning and Preventative Maintenance 15 Food Safety 17 Service 18 Wiring Diagrams 23 Limited Warranty 25 ...

Page 3: ...tware updates and additional product information Your personal information will not be shared with any other company www alto shaam com warranty Alto Shaam 24 7 Emergency Repair Service Call Call 800 558 8744 to reach our 24 hour emergency service call center for immediate access to local authorized service agencies outside standard business hours The emergency service access is provided exclusive...

Page 4: ...am Tech Team Service Department if you have any questions concerning installation operation or maintenance 1 800 558 8744 servicedept alto shaam com CAUTION Appliance and accessories may be heavy To prevent serious injury always use a sufficient number of trained and experienced workers when moving or leveling appliance and handling accessories Environmental Conditions Operational Environmental Con...

Page 5: ...and request an inspection Mail a written confirmation to the carrier s office with the time date and the person called 7 Save any packages and packing material for further inspection by the carrier 8 Promptly file a written claim with the carrier and attach copies of all supporting paperwork Alto Shaam will continue our policy of assisting our customers in collecting claims which have been properl...

Page 6: ...raining operators Additional manuals are available from the manufacturer Read all instructions in this manual carefully before installing this appliance using the appliance or performing routine maintenance Following procedures other than those indicated in this guide to use and clean the appliance is considered inappropriate and may cause damage injury or fatal accidents in addition to voiding th...

Page 7: ...s and parts lists included in this manual are for general reference only and are intended for use by qualified and trained technicians This manual should be considered a permanent part of this appliance This manual and all supplied instructions diagrams schematics parts lists notices and labels must remain with the appliance if the item is sold or moved to another location NOTICE Indicates informa...

Page 8: ...ious injury Be extremely careful when moving appliances because the food trays may contain hot fluids that may spill causing serious injury Always open the appliance door very slowly Escaping hot vapors or steam can cause serious injury If the gas appliance is installed under an exhaust hood the hood must be switched On when the appliance is in use to avoid the build up of combustion gases Failure...

Page 9: ...f any obstructions blocking access for maintenance or service 6 Lift the Breath Guard up and slide into place in brackets found in the front of the appliance A number of adjustments are associated with initial installation and start up Installation and start up adjustments are the responsibility of the dealer or user These adjustments include but are not limited to leveling electrical hook up and ...

Page 10: ... x 406mm x 13mm BA 28482 Carving Holder Prime Rib HL 2635 Carving Holder Steamship 4459 Breath Guard Kit 5012582 24 5 8 626mm without breath guard 7 8 22mm Cord to edge 31 3 16 792mm 17 1 2 444mm 16 11 16 424mm Heated Surface 14 13 16 376mm Heated Surface 18 3 16 463mm without breath guard 18 3 8 466mm with breath guard 9 1 8 232mm Cord 1 9 16 39mm 25 7 8 657mm with breath guard 29 5 8 753mm ...

Page 11: ...13 16 782mm with breath guard 25 3 4 654mm without breath guard 18 13 16 477mm 33 3 16 842mm Accessories Full Size Cutting Board 21 5 8 x 21 5 8 x 1 2 550mm x 550mm x 13mm BA 28066 Half Size Cutting Board 10 3 4 x 21 5 8 x 1 2 273mm x 550mm x 13mm BA 29244 Carving Holder Prime Rib HL 2635 Carving Holder Steamship 4459 Breath Guard Kit 5009074 Heated product capacity Weight maximum 70 lbs 31 7 kg M...

Page 12: ...12 MN 29250 Rev 6 05 18 Carving Station Installation 18 3 8 466mm 35 7 16 900mm 63 1 16 1601mm 35 1 2 901mm 65 1650mm 25 7 8 657mm CS 100 over 500 CS 200 over 750 ...

Page 13: ...cordance with applicable electrical codes This appliance must be adequately grounded in accordance with local electrical codes or in the absence of local codes with the current edition of the National Electrical Code ANSI NFPA No 70 In Canada all electrical connections are to be made in accordance with CSA C22 1 Canadian Electrical Code Part 1 or local codes CE approved appliances include an equip...

Page 14: ...ch for the lamp s to the On position 2 Preheat the carving station Preheat the carving station for a minimum of 30 minutes 3 Transfer hot foods to the carving station The hot food product must be at the proper internal temperature before transferring food to the cutting board Use a thermometer to check the internal temperature of the food being held Adjust the carving station temperature to give t...

Page 15: ...less steel surfaces Failure to observe this precaution will void the warranty Always use the proper cleaning agent at the manufacturer s recommended strength Contact your local cleaning supplier for product recommendations Cleaning Materials Cleaning can usually be accomplished with the proper cleaning agent and a soft clean cloth When more aggressive methods are needed use a non abrasive scouring...

Page 16: ... with a clean damp cloth Do not use commercial or household cleaners that contain ammonia Wipe with a clean damp cloth to remove all detergent residue Dry with a clean lint free cloth NOTICE Avoid the use of abrasive cleaning compounds chloride based cleaners or cleaners containing quaternary salts Never use hydrochloric acid muriatic acid on stainless steel 5 Wipe surfaces with a sanitizing solut...

Page 17: ...ersonal hygiene proper handling of raw foods cooking to a safe internal product temperature and the routine monitoring of internal food temperatures from the time the food is received through the time the food is served A controlled holding environment for prepared foods is just one of the important factors involved in the prevention of food borne illnesses Temperature monitoring and control durin...

Page 18: ...1 19 25 24 9 6 23 40 39 40 14 22 38 11 33 7 13 16 27 45 44 32 28 10 35 15 12 30 1 18 4 43 42 36 26 37 15 34 29 17 12 3 1 40 39 40 4 33 DETAIL A DETAIL D DETAIL B DETAIL C B D 33 201401 201402 CS 100 Part numbers and drawings are subject to change without notice ...

Page 19: ...ck Yellow IN 22265 1 23 White Pilot Light 120V LI 3027 1 White Pilot Light 230V LI 3951 1 24 Bulb Heat Lamp 120V LP 35721 1 Bulb Heat Lamp 230V LP 33781 1 25 Lamp Assembly Single 120V 5021624 1 Lamp Assembly Single 230V 5021625 1 Socket Replacement 120V SK 35730 1 Socket Replacement 230V SK 35028 1 26 Nut 1 4 20 Hex S S NU 2437 4 27 Nut Threaded Insert M6 NU 22770 1 28 Relay SPST 30A 277 VAC 12VDC...

Page 20: ...ation Service 201301 201302 A 19a 19b 30 18 23 32 32 22 4 6 21 39 38 39 37 10 14 15 13 31 5 8 32 39 38 39 9 29 33 35 42 24 41 3 16 17 7 27 26 34 28 12 36 29 1 28 2 11 Part numbers and drawings are subject to change without notice CS 200 ...

Page 21: ...m Thick Tempered GL 28604 1 20 21 White Pilot Light 120V LI 3027 1 White Pilot Light 230V LI 3951 1 22 Bulb Heat Lamp 120V LP 35721 2 Bulb Heat Lamp 230V LP 33781 2 23 Lamp Assembly Dual 120V 5021622 1 Lamp Assembly Dual 230V 5021623 1 Socket Replacement 120V SK 35730 1 Socket Replacement 230V SK 35028 1 24 Nut 1 4 20 Hex S S NU 2437 4 25 Nut Threaded Insert M6 NU 22770 1 26 Nut 8 32 UNC KEPS ZP N...

Page 22: ...mpered 5mm Upper GL 29240 1 4 Glass tempered 5mm Lower GL 29241 1 5 Screw 8 32x3 8 1 2 dia head SC 2816 8 CS 100 5012582 Item Description Part No Quantity 1 Bracket 1011870 2 2 Frame FR 28944 1 3 Glass tempered 5mm Upper GL 28416 1 4 Glass tempered 5mm Lower GL 28604 1 5 Screw 8 32x3 8 1 2 dia head SC 2816 8 CS 200 5009074 Breath Guard Kits ...

Page 23: ... MN 29250 Rev 6 05 18 Carving Station 23 Wiring Diagrams ...

Page 24: ...24 MN 29250 Rev 6 05 18 Carving Station Wiring Diagrams ...

Page 25: ...but not limited to compounds containing chloride or quaternary salts poor water quality or equipment with missing or altered serial numbers 5 Damage incurred as a direct result of poor water quality inadequate maintenance of steam generators and or surfaces affected by water quality Water quality and required maintenance of steam generating equipment is the responsibility of the owner operator 6 D...