MN-36608 • Rev 5 • 06/18 • 20-20MW, 20-20W Hot Food Holding Cabinets
Electrical Connection
1. An identification tag is permanently mounted on the
cabinet.
2. Plug the unit into a properly grounded receptacle
only. Arcing will occur when connecting or
disconnecting the unit unless all controls are in the
“Off” position.
3. Position the unit so the cord is easily accessible in
case of any emergencies. If necessary, a proper
receptacle or outlet configuration, as required for
the unit, must be installed by a licensed electrician in
accordance with applicable, local electrical codes.
WARNING
To prevent serious injury, death, or
property damage:
All electrical connections must be
made by a qualified and trained service
technician in accordance with applicable
electrical codes.
This appliance must be adequately
grounded in accordance with local
electrical codes or, in the absence of local
codes, with the current edition of the
National Electrical Code ANSI/NFPA No.
70. In Canada, all electrical connections
are to be made in accordance with CSA
C22.1, Canadian Electrical Code Part 1 or
local codes.
CE-approved appliances include an
equipotential-bonding terminal marked
with the symbol shown on the left .
Provisions for earthing are to be made in
accordance with IEC:2010 60335-1 section
27 or local codes.
WARNING
To prevent SERIOUS INJURY, DEATH or
PROPERTY DAMAGE:
All electrical connections must be made
by a qualified and trained service
technician in accordance with applicable
electrical codes.
CAUTION
Power source must match voltage identified
on appliance rating tag. The rating tag
provides essential technical information
required for any appliance installation,
maintenance or repairs. Do not remove,
damage or modify the rating tag.
Hard wired models
Hard wired models must be equipped with a country
certifi ed external allpole disconnection switch with
suffi cient contact separation. Hard wired models that are
mounted on casters must have a strain relief device (tether)
to prevent strain on the power supply cord. If a power cord
is used for the connection of the product an oil resistant
cord like H05RN or H07RN or equivalent must be used.
NOTICE:
Where local codes and CE regulatory
requirements apply, appliances must be
connected to an electrical circuit that is
protected by an external GFCI outlet.
Wire diagrams are located under the top cover of the appliance.
Electrical
V Ph Hz A kW
208 1 50/60 10.8 2.2
NEMA 6-15P
240 1 50/60 12.5 3.0
15A-250V Plug
230 1 50/60 12.0 2.8
Plugs rated 250V
CH2-16P
BS 1363
AS/NZS 3112
CEE 7/7