MN-28953 (Rev 0) • 09/13 • AR-7H Hot Holding Rotisserie Companion Operation & Care Manual • 5
I N S T A L L A T I O N
The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National
Electrical Code and applicable local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the “
off
” position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
After wiring and power connection has been
completed, turn the main power switch to the “
on
”
position. The main power switch can be left “
on
”
for daily use, but should be turned “
off
” when
cleaning or performing maintenance or repairs to
the rotisserie.
REGARDING INTERNATIONAL STANDARD UNITS:
If the unit is not equipped with flexible cord with
plug, an all-pole country approved disconnection
device which has a contact separation of at least
3mm in all poles must be incorporated in the fixed
wiring for disconnection. When using a cord
without a plug, the green/yellow conductor shall
be connected to the terminal which is marked with
the ground symbol. If a plug is used, the socket
outlet must be easily accessible. If the power cord
needs replacement, use a similar one obtained
from the distributor.
E L E C T R I C A L C O N N E C T I O N
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
D A N G E R
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE IDENTIFIED
ON APPLIANCE RATING TAG.
For CE approved units: To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts
to provide sufficient protection against potential
difference. The terminal is marked
with the following symbol.
Wire diagrams are located in the
inside access panel of the unit
ELECTRICAL
Ω
VOLTAGE
Ω
PHASE CYCLE
/
HZ AMPS K
W
120
1
60
15.0 1.8
NEMA
5-20P
20A, 125V
PLUG
208
240
1
1
60
60
8.5
9.5
1.8
2.3
NEMA
6-15P
15A, 250V
PLUG
230
1
50/60
9.0 2.1
CEE
7/7
PLUG
RATED
250V
CH
2-16
P
PLUG
RATED
250V
NOTE
:
Where local codes and CE regulatory
requirements apply, appliances must be
connected to an electrical circuit that is
protected by an external GFCI outlet.
Hard wired models:
Hard wired models must be equipped with a
country certified external allpole disconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
product an oil resistant cord like H05RN or H07RN
or equivalent must be used.
Summary of Contents for AR-7H ELECTRONIC CONTROL
Page 26: ...MN 28953 Rev 0 09 13 AR 7H Hot Holding Rotisserie Companion Operation Care Manual 24...
Page 27: ...MN 28953 Rev 0 09 13 AR 7H Hot Holding Rotisserie Companion Operation Care Manual 25...
Page 28: ...MN 28953 Rev 0 09 13 AR 7H Hot Holding Rotisserie Companion Operation Care Manual 26...
Page 29: ...MN 28953 Rev 0 09 13 AR 7H Hot Holding Rotisserie Companion Operation Care Manual 27...
Page 30: ...MN 28953 Rev 0 09 13 AR 7H Hot Holding Rotisserie Companion Operation Care Manual 28...
Page 31: ...MN 28953 Rev 0 09 13 AR 7H Hot Holding Rotisserie Companion Operation Care Manual 29...