E-87
EEPROM Error
Stored offsets corrupted Offsets reset to 0
Control may need a recalibration. Possible
bad EEPROM. Contact factory if problem
persists.
E-88
EEPROM Error
All timer setpoints are reset to 1 minute.
Timers, if previously on, are now off.
Possible bad EEPROM
E-90
Button stuck
A button has been held down for > 60
seconds. Adjust control Error will reset
when the problem has been resolved
E-91
Input failure
Contact factory
E-dS
Datakey error
Datakey digital signature incompatible.
Cycle power, and install compatible Datakey
if error persists
E-dT
Datakey error
Datakey incompatible with control. Install
compatible Datakey.
E-dU
Datakey unplugged
Install Datakey and cycle power to control
to clear error.
dLto
Datalogger has timed out
Cycle power. Contact factory if error
persists.
dLSD
Micro SD card not plugged in
Plug in SD card and cycle power. Contact
factory if error persists.