T
R O U B L E S H O O T I N G
T
R E E S
s #
/ - " ) 4 ( % 2 -
# 4 %
8 0 2 % 3 3
4
% # ( . ) # ! ,
3
% 2 6 ) # %
-
! . 5 ! ,
s $ n
13
T R O U B L E S H O O T I N G T R E E S
N o S m o k e
Is smoke icon selected?
Is the browning vent
closed?
Is there voltage across terminal
1-6 at the smoke element?
Select smoke function and
start a cycle
No
Yes
Yes
No
Smoke will not function if
browning vent is open as detected
by browning vent switch
No
Yes
L1/1 from RBH X3/306
through SK 3A Fuse (test
fuse) L2/6 from TB
Ohm out element and replace
if necessary
Is element drawing current?
No
Smoke cycle is operating
Yes
If still low or no smoke production taking
place refer to the operation/care manual for
proper operating procedures