I N S T A L L A T I O N A N D I N S T R U C T I O N M A N U A L
9
STAND-ALONE FIXED UV INTENSITY MODE
While in stand-alone mode, the hundreds button cycles through 'r', 'G', 'b', and 'A'. colors . (r = UV1; G
= UV2; b = UV3; A = N/A). The tens and ones digits select 0-99 values. 99 is actually full. The 0-255
scale is spread evenly over the 0-99 display range.
NOTE: when you go in or out of fixed intensity mode, the display will go blank. Touch any button to
turn on display.
Locked Mode
To Lock (or unlock) the buttons:
>Wait a few seconds until the display goes blank,
> press and hold the [ ONES ] button
> press and hold the [ HUNDREDS ] button
> release the [ ONES ] button
> release the [ HUNDREDS ] button.
Display will show
Loc
for a moment and then blink.
Buttons will have no effect until they are unlocked.
Master and Slave Mode
To Turn On (or Off) the MASTER:
>Wait a few seconds until the display goes blank,
> press and hold the [ HUNDREDS ] button
> press and hold the [ ONES ] button
> release the [ HUNDREDS ] button
> release the [ ONES ] button.
Display will show
ON or OFF
for a moment and then blink.