background image

Luminaire Features

17

Gallery Series LED Luminaires

Installation & User’s Manual

Figure 12:  Zoom Spot Models - Beam Control

4-Blade Shutter

Gallery  Series  LED  Luminaires  with  zoom  spot  lenses  have  a  gate  assembly  that  contains  four-blade
shutters that can be moved by hand in and out of the beam for shutter cuts. The can moved as needed
either straight out (or in) or at an angle. 

Figure 13

 shows the gate and the four shutter blade handles.

Figure 13:  Zoom Spot Models - Shutter Blades

Side of Luminaire

Bottom of Luminaire

(A)

Notes:

(A) 

Focus Knob

(B) 

Zoom / Beam Angle Knob

(C)

 All zoom lens tubes are equipped with a graduated scale.

15 - 35 Degree Zoom Basic Settings

(B)

(C)

25 - 50 Degree Zoom Basic Settings

Front of Luminaire

Narrow (25 Degrees)

Wide (50 Degrees)

Front of Luminaire

Narrow (15 Degrees)

Wide (35 Degrees)

Zoom Spot

Models

Note: Luminaire shown in exploded view for clarity. Track
model shown, same for all zoom spot models.

Shutter Blade (x4)

Lens Tube

Gate Assembly*

LED Engine

Gobo Slot

* Gate Assembly Notes:

Gate Assembly must be installed with shutter blades 
closest to lens tube for proper focusing and optimal 
performance.

Gate Assembly can rotate 360 degrees for gobo or 
shutter cuts.

Summary of Contents for GALLERY SERIES

Page 1: ... 5 6 5 6 80 1 5 6 QVWDOODWLRQ 8VHU V 0DQXDO ...

Page 2: ...m or contact your nearest Altman Lighting Regional Manager El contenido de este manual es solamente para información y está sujeto a cambios sin previo aviso Altman Lighting con no asume responsabilidad por errores o omisiones que puedan aparecer Cualquier comentario sugerencia o corrección con respecto a este manual favor de dirijirlo a la oficina de Altman Lighting más cercana Der Inhalt dieses ...

Page 3: ...ving fuses or turning the main circuit breaker off before installation Installing the device with power on may expose you to dangerous voltages and damage the device A qualified electrician must perform this installation WARNING Refer to National Electrical Code and local codes for cable specifications Failure to use proper cable can result in damage to equipment or danger to personnel WARNING Thi...

Page 4: ... faulty material or workmanship Under these same terms products with an LED light source shall be warranted for a period of THREE 3 years Altman warrants for NINETY 90 days any spare part it manufactures On spare parts or products Altman does not manufacture including but not limited to lamps sockets lenses roundels electronics ignitors ballasts etc Altman will grant the same warranty given Altman...

Page 5: ...view Gallery Series LED Luminaires Components 6 Short and Long Zoom Luminaires 6 Beam Wash Luminaires 6 Flood Luminaires 7 Installation and Set Up Top Box Overview 8 Power Requirements 9 Connecting Power 9 MAINs Dimming Versions 9 Smart Track Mount Models 10 0 10V Controlled Models Sink Current 11 Canopy Pendant Mount Models 12 Connecting to the DMX512 Network 13 Connection Block Terminal 13 RJ45 ...

Page 6: ...ts Troubleshooting Troubleshooting Guide 22 Technical Specifications Gallery Series LED Luminaires Common Specifications 23 Gallery Series LED Luminaires Dimensions 24 15 to 35 Degree Long Zoom Models 24 25 to 50 Degree Short Zoom Models 24 Beam Wash Models 25 Flood Models 25 ...

Page 7: ...or B Black or W White Gallery Series LED Luminaires Other Accessories Specify color at time of ordering by adding the following code for color B Black or W White All portable units use RJ45 Connectors for DMX connectivity For connectivity to any DMX 5 pin system you will need part num bers RJ45F DMXF and RJ45F DMXM Part Number Description GAL2550LT Additional 25o 50o Short Zoom Lens Tube note requ...

Page 8: ...Beam Wash Luminaires Figure 2 shows the basic features of Beam Wash Gallery Series LED Luminaires Figure 2 Beam Wash Luminaire Features Top Box portable models Top Box track models LED Engine Yoke Arm Yoke Tilt Knob Zoom Lens Tube Gate Assembly with shutters Zoom Lens Tube Gate Assembly with shutters LED Engine Refer to Top Box Overview on page 8 for more information Top Box portable models Top Bo...

Page 9: ...he features illustrated in this section is to familiarize users with the basic components and features of the fixtures The next chapters will provide detailed information on connections and mounting For technical specifications refer to Technical Specifications on page 23 Top Box portable models Top Box track models LED Engine Yoke Arm Yoke Tilt Knob Flood Lens Flood Lens Refer to Top Box Overview...

Page 10: ...gure 4 shows the features and connections on the two versions of the Gallery Series Luminaire top boxes Figure 4 Top Box Overview Features C Clamp Unistrut Mounting Point mounting hole 1 2 in 12 7 mm IEC Connection AC Input DMX In Out RJ45 connections Track Adapter Safety Cable Anchor Point same for all models Ceiling Mount Portable Models C Clamp Unistrut Smart Track Track Mount Models Ceiling Pe...

Page 11: ...r IEC to Edison input cable Portable models that are mounted with a C Clamp or Unistrut Direct connection to the powered track Track Mount Smart Track Models or Ceiling Pendant Models Field wiring of the fixture is straight forward A total of three wires conductors need to be brought to the unit The following wiring scheme as shown in Table 1 is required for direct connection models Table 1 AC Inp...

Page 12: ...to utilization Please note that the majority of phase cut dimmers tested have resulted in proper dimming performance For additional information please contact customer service Smart Track Mount Models To connect Smart Track models to track Step 1 If not done at factory connect AC wiring as shown in Figure 6 Also refer to Table 1 on page 9 Figure 6 Track Adapter Power Wiring Compatible Phase Cut 12...

Page 13: ...t of approved dimmers is listed in Table on page 13 To connect power to portable models Step 1 Make sure the AC cable is not connected to an AC power source Step 2 As illustrated in Figure 8 on page 11 position AC input cable in direct relation to the IEC connector on the side luminaire top box assembly Figure 8 IEC Connector Portable Models Step 3 Press AC input cable IEC connector firmly into IE...

Page 14: ...nd junction box screws are not included with Gallery Series LED Luminaires and are by others WARNING Canopy pendant mount models must be installed by qualified professional installer and should be done in accordance with local and national codes To wire and install canopy pendant mounted models WARNING Make sure power to the junction box is completely disconnected Failure to do so could lead to se...

Page 15: ... Daisy chain it is highly recommended that a DMX TERMINATOR Altman Lighting part number DMX MPHX TERM for the connectors shown in Table 4 is utilized on the last luminaire or device in the chain For more information on installing DMX512 control systems the following publication is available for purchase from the United States Institute for Theatre Technology USITT Recommended Practice for DMX512 A...

Page 16: ...agement RDM compliant All DMX and Luminaire settings are programmed via a RDM ANSI E1 20 complaint device As many of the RDM devices and software work differently please consult the RDM programmer manufacturer for specific Table 5 DMX RJ45 XLR Connector Wiring DMX Connections RJ45 and XLR Connectors DMX Signal RJ45 Connector XLR Connector Common Drain Pin 7 Pin 1 DMX Pin 2 Pin 2 DMX Pin 1 Pin 3 A ...

Page 17: ...DM Standard Step 2 Press NEXT button on RAD Step 3 One of the RDM devices will be discovered and identify itself Step 4 RAD s display will show identified device s DMX address Identification method varies from device to device many lighting fixtures flash or strobe Step 5 Use RAD s three buttons below the display to change DMX address of identified device Step 6 After a few seconds after the addre...

Page 18: ...features User settable and lockable zoom and focus control 4 blade shutter system set on two planes Gobo slot for E size gobos measuring 37 5 mm OD with a 28 mm image area Gobo holder is included with all zoom spot models and can be purchased as an additional accessory End of lens tube accessory holder same for all models see Accessory Holder All Models on page 19 Zoom and Focus Control Zoom and f...

Page 19: ... Luminaire Bottom of Luminaire A Notes A Focus Knob B Zoom Beam Angle Knob C All zoom lens tubes are equipped with a graduated scale 15 35 Degree Zoom Basic Settings B C 25 50 Degree Zoom Basic Settings Front of Luminaire Narrow 25 Degrees Wide 50 Degrees Front of Luminaire Narrow 15 Degrees Wide 35 Degrees Zoom Spot Models Note Luminaire shown in exploded view for clarity Track model shown same f...

Page 20: ... are ideal to project a soft edge even beam of light For beam wash models beam shaping is achieved through external four flap barn doors sold separately To adjust the beam angle simply loosen do not remove the beam angle knob as illustrated in Figure 14 Once the desired angle is achieved re tighten the beam angle knob Note Keeping the beam angle knob loose and slightly snug will allow smooth movem...

Page 21: ...ls Pan Tilt All Models All Gallery Series LED Luminaires can have their pan and tilt set by hand without the use of tools To adjust pan or tilt loosen do not remove thumb screw or knob as indicated in Figure 16 and adjust pan or tilt as desired Once positioned as desired re tighten by hand or tool see note on tilt knob the thumb screw or knob Do not over tighten Figure 16 Fixture Pan Tilt ALL Mode...

Page 22: ...ollowing is a list of cleaning materials required to care for your Gallery Series LED Luminaires Lint free lens tissue Lint or powder free gloves Reagent grade isopropyl alcohol A mild soap solution Note Reagent grade isopropyl alcohol is good to use on the Gallery Series LED Luminaires plastic optics with anti reflection coatings If the lens is still dirty after using isopropyl alcohol for instan...

Page 23: ...low to cool completely Step 2 Remove lens assembly Step 3 Apply a small amount of reagent grade isopropyl alcohol to lint free lens tissue Step 4 Wipe all debris dirt fingerprints etc from lens Step 5 Using a second lint free lens tissue wipe off any alcohol residue Step 6 Once lens is completely dry reinstall lens assembly Service and Maintenance For all other service and maintenance issues pleas...

Page 24: ... low light output and connected to power Mains Dim Unit fade pot set to 0 turn local control to 100 Mains Dim unit check connected dimmer for upper threshold settings No power at luminaire Luminaire does not power up Circuit not energized verify circuit breaker is turned on Not plugged in ensure A C cable is connected to power source Power cable wired incorrectly verify power cable and connector a...

Page 25: ... 4000K and 5000K White Lumens Watt DMX DALI Models 80 MAINS 0 10 76 9 Control MAINS Models 120VAC only DALI Models Local Dim DALI Control DMX Models Local Dim DMX512A Fully RDM Compliant 0 10V Models Local Dim 0 10V BTU s Hour DMX DALI Models 170 6 MAINS 0 10 Models 177 32 Cooling Silent Active Cooling 8 dBA 0 5 M Thermal After 5 Minutes 35 Degrees Celsius Steady State 44 Degrees Celsius Ambient T...

Page 26: ...Models 25 to 50 Degree Short Zoom Models Note Track model shown Common dimensions shown for long zoom models Weight 5 85 Lbs 2 65 Kg 4 0 In 101 6 mm 15 3 In 388 6 mm 6 7 In 170 2 mm 7 9 In 200 7 mm Note Track model shown Common dimensions shown for short zoom models Weight 5 55 Lbs 2 51 Kg 4 0 In 101 6 mm 13 3 In 337 8 mm 6 7 In 170 2 mm 7 9 In 200 7 mm ...

Page 27: ...Flood Models 4 0 In 101 6 mm 7 2 In 182 9 mm 6 7 In 170 2 mm 7 9 In 200 7 mm Note Track model shown Common dimensions shown for beam wash models Weight 4 0 Lbs 1 81 Kg 4 0 In 101 6 mm 5 7 In 144 8 mm 6 7 In 170 2 mm 7 9 In 200 7 mm Note Track model shown Common dimensions shown for flood models Weight 3 77 Lbs 1 71 Kg ...

Page 28: ... OWPDQ LJKWLQJ OH DQGHU 6WUHHW RQNHUV 1HZ RUN 0DLQ D ZZZ DOWPDQOLJKWLQJ FRP OWPDQ 6WDJH LJKWLQJ QF 14 September 2016 ...

Reviews: