Installation & User’s Manual
Gallery Series LED Luminaires
s
14
Installation and Set Up
• (DMX Version Ceiling mount) One (1) piece of Category 5 Belden 1592A cable for all data connectivity.
Three (3) of the conductors are used for data input and three (3) conductors for data output. Note, the
White/Blue & Blue conductors are not used. Both Data Input and Output utilize a Phoenix Contact 3
position terminal block for use with 20-24 AWG.
Figure 11: DMX Connector Wiring
RJ45 / XLR Connectors
For models with RJ45 connectors for DMX Input / Output, refer to
Table 5
for RJ45 and XLR connector
wiring.
Note:
* Only those pins shown are used. Remaining pins on RJ45 and XLR connectors are not used.
Setting a DMX Address via RDM
Gallery Series LED Luminaires are full featured Remote Device Management (RDM) compliant. All DMX
and Luminaire settings are programmed via a RDM ANSI E1.20 complaint device. As many of the RDM
devices and software work differently please consult the RDM programmer manufacturer for specific
Table 5: DMX RJ45 & XLR Connector Wiring
DMX Connections - RJ45 and XLR Connectors
DMX Signal
RJ45 Connector*
XLR Connector*
Common (Drain)
Pin 7
Pin 1
DMX -
Pin 2
Pin 2
DMX +
Pin 1
Pin 3
(A) Insert and hold small, flat screwdriver
into slot to open wire way.
(B) Insert CAT 5 DMX cable into wire
way. Strip wire to 0.25-in / 6.5 mm.
DMX INPUT
DMX OUTPUT
White / Green (Data Out +)
Green (Data Out -)
Brown (Data Out Common)
Pin 1
Pin 2
Pin 3
White / Green (Data Out +)
Green (Data Out -)
Brown (Data Out Common)
Pin 3
Pin 2
Pin 1
Pin 1
Pin 2
Pin 3
Pin 3
Pin 2
Pin 1
White / Orange (Data In+)
Orange (Data In -)
White / Brown (Data In Common)
White / Orange (Data In+)
Orange (Data In -)
White / Brown (Data In Common)
Factory (Fixture) Wiring
Customer (Building) Wiring
Factory (Fixture) Wiring