background image

PNP415/417

PNP415/417

PNP415/417

PNP415/417

/Pop ‘N Plug

/Pop ‘N Plug

/Pop ‘N Plug

/Pop ‘N Plug

®

 with Custom Tabletop Surface

 with Custom Tabletop Surface

 with Custom Tabletop Surface

 with Custom Tabletop Surface

    

User’s Guide

    

400-0427-004 

 

 
 
 
 
 
 

Welcome! 

We greatly appreciate your purchase of the PNP415/417 Pop ‘N Plug with 
Custom Tabletop Surface. We are sure you will find it reliable and simple to 
use. Superior performance for the right price, backed by solid technical and 
customer support is what ALTINEX has to offer. 

We are committed to providing our customers with 
Signal Management Solutions

®

 to the most demanding audiovisual 

installations at very competitive pricing and we welcome you to join the 
ranks of our many satisfied customers throughout the world. 

1. Precautions and Safety Warnings 

Please read this manual carefully before using your PNP415/417 
Interconnect Box. Keep this manual handy for future reference. These safety 
instructions are to ensure the long life of your PNP415/417 and to prevent 
fire and shock hazards. Please read them carefully and heed all warnings. 

1.1 General 

 

Unauthorized personnel shall not open the unit since there are 
high-voltage components inside. 

 

Qualified ALTINEX service personnel, or their authorized 
representatives, must perform all service 

1.2 Installation Precautions 

 

For best results, place the PNP415/417 in a dry area away from dust and 
moisture. 

 

To prevent fire or shock, do not expose this unit to water or moisture. 
Do not place the PNP415/417 in direct sunlight, near heaters or 
heat-radiating appliances, or near any liquid. Exposure to direct 
sunlight, smoke, or steam can harm internal components. 

 

Handle the PNP415/417 carefully. Dropping or jarring can damage the 
unit. 

 

Never place fingers inside the openings of the unit. This action could 
cause serious injury due to sharp edges inside the PNP415/417. 

 

Do not place heavy objects on top of the PNP415/417. Do not use 
excessive force to push down on the top of the unit.  

 

To turn off the main power, disconnect the power cord which powers 
the AC socket on the PNP415/417 pop-up panel. The power outlet used 
should be installed as near to the equipment as possible and should be 
easily accessible. 

 

ALTINEX recommends using wall outlets with a Ground Fault Circuit 
Interrupter (GFCI) for maximum protection. 

 

Install all cables according to the instructions. Do not force or pull out 
any cable or power cord that is attached to the PNP415/417. 

1.3 Cleaning 

 

Surfaces should be cleaned with a dry cloth. Never use strong 
detergents or solvents such as alcohol or thinner. Do not use a wet cloth 
or water to clean the unit. 

1.4 FCC Notice 

 

This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions: (1) This device may not cause 
harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation. 

 

This equipment has been tested and found to comply with the limits for 
a Class A digital device, pursuant to Part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial 
environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with the 
instructions found herein, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is 
likely to cause harmful interference in which case the user will be 
required to correct the interference at his own expense. 

 

Any changes or modifications to the unit not expressly approved by 
ALTINEX, Inc. could void the user’s authority to operate the 
equipment. 

 

 

 

2. Installation Procedures 

Step 1. 

Refer to the ALTINEX website, 

www.altinex.com

, to download the latest templates and instructions for tabletop cutting requirements and installation 

instructions.  In order to do this, locate the PNP415 or PNP417 on the website and go to its detail page. The links to the templates, user guide, and 
more are on the details page. 

Step 2. 

Print all information applicable to the installation of the PNP415/417, including the templates and any detailed installation instructions. 

Step 3. 

Cut an opening into the table’s surface. This operation should be performed by experienced professionals in order to insure accuracy and to be 
aesthetically pleasing. 

 

Note: Always confirm dimensions before cutting to insure that specifications have not changed. 

Step 4. 

Install the PNP415/417 into the table per the installation instructions provided on the website.  

Step 5. 

Connect all PNP415/417 cables to their appropriate sources and/or destinations. The PNP415/417 is now ready for operation. 

 

3. Limited Warranty/Return policies 

Please see the ALTINEX website at 

www.altinex.com

 for details on warranty and return policies. 

Summary of Contents for PNP415

Page 1: ...les according to the instructions Do not force or pull out any cable or power cord that is attached to the PNP415 417 1 3 Cleaning Surfaces should be cleaned with a dry cloth Never use strong detergen...

Page 2: ...Twisted Pair 4 RJ 45 male Modem 2 RJ 11 male AC Power 4 NEMA 5 15P Table 1 PNP415 417 General Mechanical PNP415 417 Min Table Thickness 0 500 in 13 mm Max Table Thickness 1 125 in 29 mm Diameter 4 950...

Page 3: ...uare A simple press on the lid closes the unit flush with the tabletop The PNP415 417 design allows the connector panels to be easily installed Just remove the top and slide the connector panels into...

Page 4: ...PNP415 417 PNP415 417 PNP415 417 PNP415 417 User s Guide 400 0427 004 4 6 Application Diagrams Diagram 1 Typical Setup PNP417 REVERSE SIDE OF PNP417...

Page 5: ...PNP415 417 PNP415 417 PNP415 417 PNP415 417 User s Guide 400 0427 004 5 Diagram 2 Cutout Dimensions Diagram 3 Closed Dimensions 4 950 125 73mm 5 250 133 35mm 7 736 196 49mm 6 986 177 44mm...

Page 6: ...PNP415 417 PNP415 417 PNP415 417 PNP415 417 User s Guide 400 0427 004 6 Diagram 2 Front View Dimensions 3 817 96 96mm 4 875 123 83mm 4 125 104 78mm FRONT VIEW...

Page 7: ...PNP415 417 PNP415 417 PNP415 417 PNP415 417 User s Guide 400 0427 004 7 Diagram 3 Side View Dimensions 6 000 152 40mm 7 736 196 49mm 12 611 320 32mm SIDE VIEW...

Page 8: ...Connections Connect external devices to the appropriate connector on the PNP415 417 Remember the devices plugged into the AC power connectors should not draw more than 5A AC 8 Troubleshooting Guide T...

Reviews: