MX430
MX430
MX430
MX430----101
101
101
101
User’s Guide
400-0548-001
5
7. Operation
7.1 Manual Control
7.1.1 Power Key
If the POWER LED is RED, the MX430-101 is in standby mode. Press
the POWER key to turn on the system.
The POWER LED turns GREEN and the system initializes;
initialization takes about 10 seconds. During this time the ENTER LED
flashes; the ENTER LED turns off when the system is ready.
Press the POWER key when the LED is GREEN and the system goes
into standby mode and the LED turns RED.
7.1.2 Input Switching
The MX430-101 has 8 keys that are used to select both inputs and
outputs. In the LCD display, Outputs are distinguished using letters
A-H representing Outputs 1-8 while Inputs are simply 1-8.
Switch One Input to One Output
To make a simple switch, first select an output, A-H. The ENTER LED
turns on. Next, press an Input key. The new connection is displayed in
the LCD window but the physical switch is not made until the ENTER
key is pressed. For example, to connect Output 8 to Input 2 execute
the following key strokes:
8 + 2 + ENTER
Switch One Input to ALL 8 Outputs
To make a broadcast connection, first press the ALL key. Next, press
an Input key. The new connection is displayed in the LCD window
but the physical switch is not made until the ENTER key is pressed.
For example, to connect Input 1 to ALL outputs execute the following
key strokes:
ALL + 1 + ENTER
7.1.3 SAVE & RECALL SWITCHER SETTINGS
The MX430-101 has 6 memory locations available to save popular
switcher configurations.
Recall
Press the RECALL key and the current saved configurations are
displayed in the LCD window. Configurations 1, 3, and 5 are on the
left side of the display and 2, 4, and 6 are on the right side of the
display. Press a number key 1-6 to select the configuration and then
ENTER to recall the switch settings.
Save
Save the current switch settings by pressing the MEMORY key, the
memory location 1-6, and then ENTER. This overwrites the switcher
settings currently in that memory location and makes the current
settings available for recall.
7.1.4 FRONT PANEL LOCK
Press the LOCK key to lock the front panel and prevent accidental
switching of the matrix. The LOCK LED is on when the panel is
locked. Press the LOCK key again to unlock the front panel.
7.1.5 EDID
Each input can be individually set for STANDARD MODE to use the
internal EDID memory of the switcher or TV MODE to use the EDID
memory of one of the external displays on Outputs 1-4 (A-D).
In TV MODE the switcher automatically detects and uses the first
HDMI output EDID it scans with first priority on Output 1/A. TV
MODE is the default setting and is typical for most applications.
In STANDARD MODE, the switcher uses internal EDID memory for
selected inputs. STANDARD MODE supports video formats up to
1080p 10 bits and audio coded for PCM2.
7.2 Remote Control
7.2.1 Input Switching
The IR receiver is on the front of the switcher to the right of the LCD
window. Aim the remote at the front of the switcher. Press a single
digit to represent the Output number 1-8 (A-H). Next, select a single
digit represent the Input number 1-8. The switcher makes the switch
and updates the LCD window.
7.2.2 IR Receiver
The IR receiver included with the switcher plugs into the IR IN jack
on the rear of the switcher. The IR IN jack is a standard 3.5 mm jack
with the following pinout:
7.3 RS-232 Control
The MX430-101 has many advanced remote-control capabilities accessible
through standard RS-232 communication. Control may be accomplished
through a computer, control system, or any device capable of RS-232
communication.
7.3.1 RS-232 Serial Port Settings
In order to configure the switcher or to control it using RS-232
communication, make sure the communication software is set for the
following:
Baud Rate ................. 9600
Data Bits ................... 8
Stop Bits .................... 1
Parity ........................ None
Flow .......................... None