400-0742-001 

 

 
 
 
 
 
 

 

5. Operation 

5.1 Control 

The MT318-101 has many advanced remote-control 
capabilities when used in the MultiTasker enclosure. These 
capabilities are accessible through standard RS232 or TCP/IP 
communication. The actual controlling can be accomplished 
through a computer control system or any other device capable 
of sending commands. 

5.1.1 RS232/TCP Interface  

This section lists all the RS232/TCP control and configuration 
command formats and their ranges.  

The TCP/IP ports have the following default settings: 

IP address ... 192.168.10.84  

Port.............. 23 

The rear panel RS232 port has the following settings: 

Baud ............ 115k 

Data bits ...... 8 

Stop bits ...... 1 

Parity ........... None 

Flow ............. None 

5.1.2 Command Basics 

The control commands for the MT318-101 are in a simple 
ASCII character format. 

1.  Square brackets "[ ]" are part of the command. 

2.  Use uppercase letters for all commands. 

3.  Spaces are NOT legal characters. 

4.  Do NOT send carriage returns or line feeds;  

these are invalid characters. 

A command that instructs the card only to perform an action 
will generate feedback of "[

Card ID

]". The open bracket 

followed by the card ID and then a close bracket indicates the 
card received and executed a valid command.  If the command 
requested information from the card, the feedback generated 
by the card is the acknowledgement of having received a valid 
command.  

[C04] 

Card C4 (slot 4) executed a valid command 

Invalid commands generate feedback that includes "ER" and 
may also include an error code. 

[ERC04] 

Card C4 (slot 4) failed to execute a command 
Check command syntax. 
Check values sent are within a valid range. 

Commands ending in "S" will be saved into memory. 
Commands not ending in "S" are executed, but not restored at 
reset or power up. 

 

5.1.3 Conventions Used in this Manual 

Card IDs: 

In this manual, cards are referenced by their card ID which is 
equivalent to their slot number: 

C1, C2, C3, C4 ... C20 

Group IDs: 

Groups are referenced by their group ID: 

G1, G2, G3 ... G8 

5.2 Description of Commands 

A command consists of 3 parts: Function, Card ID, and Save. 

 

[ Function , Card ID  Save] 

Example:  [VERC4] 

VER 

= Function 

C4 

= Card ID or Group ID 

= Save this setting (optional) 

The card ID is a unique identifier, equal to the enclosure slot 
number. As the slot number, the value can range from 1 to 20 
depending on the enclosure. 

The group ID is a number representing a group of cards 
defined with the [GROUP] command. When using the group 
ID, all cards in the group perform the same instruction. 

Changing the position of a card significantly affects the 
software definitions or third-party control systems. 

Common Commands 

1. 

[C] 

This command displays a user formatted status of the card. 

Command Format: 

[Cii] 

Example: 

Display the status of the MT318-101 card in slot 4 by 
sending the following command: 

     [C04] 

The MT318-101 returns the status in the format shown 
below. 

MT318-101 
DUAL HDBT RX     
 
RS-232:         9600,N,8,1 
RS RCV 1:       0  
RS RCV 2:       0  
CARD POWER:     32495 mW 
HARDWARE1:      ENABLED 
HARDWARE2:      ENABLED 
CARD TEMP:      32C 
GROUP:          NONE 

Summary of Contents for MT318-101

Page 1: ...Part 2 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses...

Page 2: ...tput Connectors HDBT Digital Video Audio RJ45 F 2 Table 1 MT318 101 General Mechanical MT318 101 Slots 1 Weight 0 8 lb 0 36 kg actual 0 7 lb Connector Panel Black Anodized T Operating 10 C 45 C Humidi...

Page 3: ...d a valid command Invalid commands generate feedback that includes ER and may also include an error code ERC04 Card C4 slot 4 failed to execute a command Check command syntax Check values sent are wit...

Page 4: ...3011C04 Power in milliwatts 03011 3 011 mW Card power 5 digits End status 4 S SAVE This command saves the configuration command being sent in memory Send I1O1C8S and after reset or power up Input 1 is...

Page 5: ...PWRCii Example Read the power consumption of the card in slot 4 by sending PWRC4 feedback is like the following 4 59WC04 12 PWRM Same as the PWR command but returns milliwatts Command Format PWRMCii E...

Page 6: ...ort Use this command when data from the device is expected by the control application This command may be used with the S option to set the startup state of the receive option Command Format TRRSn dd...

Page 7: ...m the controller the application can be used to respond to data received from the projector for example TEMP1 indicating its internal temperature is too high RS1TEMP1C04 Data may be returned in any of...