background image

DISTRBUTION AMPLIFIERS

2

PRECAUTIONS / SAFETY WARNINGS

1

Please read this manual carefully before using your

DA1322AT 

Distribution Amplifier. Keep this manual

handy for future reference. These safety
instructions are to ensure the long life of your

DA1322AT

 and to prevent fire and shock hazard.

Please read them carefully and heed all warnings.

1.1 GENERAL

 Unauthorized personnel shall not open the unit

since there are high-voltage components inside.

 Qualified Altinex service personnel, or their

authorized representatives must perform all
service.

1.2 SAFETY GUIDELINES FOR THE RACK-
MOUNTING OF THE DA1322AT

 Maximum operating ambient temperature is 35

(degrees C).

 Never restrict the air flow through the devices’

fan or vents.

 When installing equipment into a rack, distribute

the units evenly. Otherwise, hazardous
conditions may be created by an uneven weight
distribution.

 Connect the unit to a properly rated supply

circuit.

 Reliable Earthing (Grounding) of Rack-Mounted

Equipment should be maintained.

1.3 INSTALLATION

 For best results, place the 

DA1322AT

Distribution Amplifier on a flat, level surface in a
dry area away from dust and moisture.

 To prevent fire or shock, do not expose this unit

to rain or moisture. Do not place the 

DA1322AT

Distribution Amplifier in direct sunlight, near
heaters or heat radiating appliances, or near any
liquid. Exposure to direct sunlight, smoke, or
steam can harm internal components.

 Handle the 

DA1322AT 

Distribution Amplifier

carefully. Dropping or jarring can damage
internal components.

 Do not place heavy objects on top of the

DA1322AT

. If the 

DA1322AT 

is to be mounted,

to a table or wall, use only Altinex made
mounting accessories (Rack Mount Shelf

DA1293FC,

 Rack Mount Ears

 DA1294FC

) and

cables for optimum setup.

 To turn off the main power, be sure to remove

the cord from power outlet. The power outlet
socket should be installed as close to the
equipment as possible, and should be easily
accessible.

 Do not pull power cord or any cable that is

attached to the 

DA1322AT 

Distribution Amplifier.

 If the 

DA1322AT 

Distribution Amplifier is not

used for an extended period, disconnect the
power cord from the power outlet.

1.4 CLEANING

 Unplug the 

DA1322AT 

power cord before

cleaning. Clean surfaces with a dry cloth. Never
use strong detergents or solvents such as
alcohol or thinner. Do not use a wet cloth or
water to clean the unit.

1.5 FCC / CE NOTICE

 This device complies with Part 15 of the FCC

Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.

 This equipment has been tested and found to

comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial
environment. This equipment generates, uses,
and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications. Operation
of this equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference
at his own expense.

Summary of Contents for Distribution Amplifier DA1322AT

Page 1: ...DISTRIBUTION AMPLIFIERS MANUAL PART NUMBER 400 0066 003 PRODUCT REVISION 2 DA1322AT 1 IN 2 OUT RGBHV DISTRIBUTION AMPLIFIER W EQ GAIN USER S GUIDE...

Page 2: ...o visual installations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the world This...

Page 3: ...of the DA1322AT If the DA1322AT is to be mounted to a table or wall use only Altinex made mounting accessories Rack Mount Shelf DA1293FC Rack Mount Ears DA1294FC and cables for optimum setup To turn...

Page 4: ...Y R Y B Y S Video Y C and Composite Video by using the appropriate channels The DA1322AT uses a universal linear power supply with continuous operation between 95 240V AC TECHNICAL SPECIFICATIONS 3 F...

Page 5: ...ISTRBUTION AMPLIFIERS 4 100MHz on Coupling DC Cross talk 40dB 10MHz Power Internal Power Adapter 95 240 V Continuous Power Consumption 10 watts max Table 3 DA1322AT Electrical DESCRIPTION OF DA1322AT...

Page 6: ...ED GREEN BLUE inputs with 75 Ohms The GAIN switch is used to set gain to 1 or 1 3 The EQLZ switch is used to compensate for longer cable runs APPLICATION DIAGRAM 5 4 3 SYNC CONTROL SWITCHES The DA1322...

Page 7: ...uality cable CONGRATULATIONS YOU ARE DONE OPERATION 7 The settings of the DA1322AT Distribution Amplifier can be adjusted using the Channel dip switches and Sync control switches as described in Secti...

Page 8: ...you may have RGBS You may also have RGBS on the input and RGBHV on the output 5 May I use You can not use cat 5 cable cat 5 cable instead of coaxial cable instead coaxial cable because you will loose...

Page 9: ...roducts that you have ordered and that this product fulfills your need In the unlikely event that an Altinex product needs to be returned please follow the policies below Altinex will accept product r...

Reviews: