background image

DISTRIBUTION AMPLIFIERS

8

ALTINEX POLICY

11

11.1 LIMITED WARRANTY

Altinex warrants that its products and cables are
free from defects in materials under normal use
and service. This warranty is limited to repairing
at company’s factory any part or parts of the
product, which upon company’s examination
shall disclose to be, thus defective. Products
considered defective should be returned to
company with transportation charges pre-paid
within 2 years (90 days for cables) from date of
shipment to the purchaser. The warranty is
expressly instead of all other warranties
expressed or implied. Altinex neither assumes
nor authorizes any other person to assume for it
any other liability in connection with the sale of
the products. This warranty shall not apply to
any product that shall have been repaired or
altered outside of company’s factory in any way
so as, in its judgment, to affect its stability or
reliability, or that has been subject to misuse,
negligence or accident.

11.2 RETURN POLICY

It is very important to Altinex that you receive the
product that you have ordered and that this
product fulfills your need. In the unlikely event,
that an Altinex product needs to be returned
please follow the policies below:

Altinex will accept product returns for a period of
30 days from authorized Altinex dealers.
Products must be returned in an unopened
package.

If product has been opened, the restocking fees
will apply. For the restocking fee amount, please
contact an Altinex Sales Representative.

If product is in your possession for more than 30
days, the restocking fees will apply.

Altinex will not accept any returns on cables or
custom products.

If your product is in warranty and needs service,
contact the Altinex Sales Department for an
RMA (Return Material Authorization). Products
returned without an RMA number may
experience a delay in service.

If your product is out of warranty and needs
service, contact the Altinex Sales Department
for an RMA (Return Material Authorization).
Products returned without an RMA number may
experience a delay in service. The service
charges will be quoted to you before the actual
repairs are done.

11.3 CONTACT INFORMATION

Sales Department

Phone: 

714-990-2300

Fax: 

714-990-3303

Accounting Department

Phone: 

714-990-6088

Fax: 

714-990-5778

Summary of Contents for DA1206RM

Page 1: ...DISTRIBUTION AMPLIFIERS MANUAL PART NUMBER 400 0002 003 PRODUCT REVISION 1 DA1206RM 1 IN 2 OUT RGBS DISTRIBUTION AMPLIFIER USER S GUIDE ...

Page 2: ...ng audio visual installations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the world This manual covers DA1206RM 1 in 6 out RGBS high resolution video distribution amplifier TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 GENERAL 2 RACK MOUNT SAFETY GUIDELINES 2 INSTALLATION 2...

Page 3: ... Do not place heavy objects on top of the DA1206RM If the DA1206RM is to be mounted to a table or wall use only Altinex made mounting accessories Rack Mount Shelf DA1298FC Rack Mount Ears DA1299RM and cables for optimum setup To turn off the main power be sure to remove the cord from the power outlet The power outlet socket should be installed as close to the equipment as possible and should be ea...

Page 4: ... with various displays The DA1203RM Distribution Amplifier is a state of the art product with a video bandwidth of 350 MHz enabling it to remain transparent to the video signal passing through it Each output is individually buffered and is not affected by other output loading The DA1206RM offers an internal 90 140 200 240V power supply and can be rack mounted using optional hardware accessories DA...

Page 5: ...DISTRIBUTION AMPLIFIERS 4 Vertical 47 180 Hz Power Internal Power Supply 90 140V 200 240V Table 3 DA1206RM Electrical DESCRIPTION OF DA1206RM 4 ...

Page 6: ... 4V sync level is used This should be considered as the default setting The 2V setting allows compatibility with some older equipment that would be overdriven if a stronger signal were used APPLICATION DIAGRAM 5 4 3 VIDEO LEVEL SWITCH The VIDEO LEVEL Switch can be set to either the standard 0 7V output or to 1 0V output When the switch is set in the 1 0V output position this provides approximately...

Page 7: ...cribed in Section no 4 There are no other adjustments necessary to operate the unit The DA1206RM will operate successfully as long as cables are attached properly and other technical specifications are followed ACCESSORIES 8 Model No Description TABLE MOUNT BRACKET TM1276 Table Mount Bracket for 2U High rack units RACK MOUNTING BRACKETS DA1298RM Rack Mount shelf for two units DA1299RM Rack Mount s...

Page 8: ...o positions 2V and 4V Most often a 4V Sync Level is used This should be considered as the default setting The 2V setting allows compatibility with some older equipment that would be overdriven if stronger signal is used 6 What should I This provides have when the Video Level switch is set in the 1 0V output position approximately a 35 increase in the video signal level This can be used in installa...

Page 9: ... receive the product that you have ordered and that this product fulfills your need In the unlikely event that an Altinex product needs to be returned please follow the policies below Altinex will accept product returns for a period of 30 days from authorized Altinex dealers Products must be returned in an unopened package If product has been opened the restocking fees will apply For the restockin...