8. Troubleshooting Guide 

We have carefully tested and found no problems in the supplied 
AC301-201. However, we would like to offer suggestions for the following: 

8.1 LED is Not Red 

There is a power LED next to the RJ-45 connector on the AC301-201. The 
LED is visible through the seam of the plastic enclosure. 

Cause 1: 

There is no power. 

Solution:  Verify the AC301-201 is connected directly to the MultiTasker 

and that the MultiTasker enclosure has power and is turned 
on. If LED is still not on, see Cause 2. 

Cause 2: 

The wrong cable is being used. 

Solution:  If there is a cable between the AC301-201 and the 

MultiTasker, verify pin 9 of the cable has continuity 
throughout the cable. If the LED is still not on, see Cause 3. 

Cause 3: 

The AC301-201 is not connected to a MultiTasker. 

Solution:  If the AC301-201 is not connected to a MultiTasker, then the 

external power adapter must be connected. Connect the power 
adapter to the AC301-201. If the LED is still not on, see 
Cause 4. 

Cause 4: 

The AC301-201 has a problem. 

Solution:  If there is still no power, the AC301-201 may require service. 

Please, call ALTINEX at (714) 990-2300. 

 

8.2 No Communication 

Cause 1: 

The devices are incompatible. 

Solution:  Connect the computer directly to the destination device using 

a standard RS-232 cable. If the devices communicate without 
the AC301-201, the problem is with the cables or AC301-201; 
see Cause 2. 

Cause 2: 

Cable connections are wrong. 

Solution 1:  Verify the output of the AC301-201 is connected to the input 

of the serial device. 

Solution 2:  Verify that the Signal Present LED on the AC301-201 is on and 

red. If the LED is on and red, check the connection between 
the computer and the AC301-201. 

Solution 3:  If the LED on the AC301-201 is red, use the DeviceInstaller as 

described in the installation section. If the AC301-201 is seen 
on the network and the LED is on and red, and there is still no 
communication, call ALTINEX at (714) 990-2300. 

 
 
 
 
 
 
 

Summary of Contents for AC301-201

Page 1: ...es and can radiate radio frequency energy and if not installed and used in accordance with the instructions found herein may cause harmful interference to radio communications Operation of this equipm...

Page 2: ...90 non condensing MTBF calculations 40 000 hrs Table 2 AC301 201 Mechanical Electrical AC301 201 Input Output Signal Serial 9 pin D Sub RS 232 Standard Ethernet LAN TCP IP 10 100 Mbps Default Setting...

Page 3: ...network LAN The IP address Internet Protocol address may be set automatically or assigned manually during the initial installation The AC301 201 is compact and easy to use It offers a male 9 pin D Sub...

Page 4: ...AC301 AC301 AC301 AC301 201 201 201 201 User s Guide 400 0446 002 4 6 Application Diagrams Diagram 1 Typical Setup AC301 201 INTERNET MULTITASKER...

Page 5: ...AC301 AC301 AC301 201 201 201 201 User s Guide 400 0446 002 5 Diagram 2 Internal View DC 6V RX DATA IN DATA OUT AC301 201 TX POWER ETHERNET TTL TX 9 PIN D Sub ETHERNET RJ 45 POWER JACK TRANCEIVER to R...

Page 6: ...a few seconds The IP Address 7 Once the device is located click on the device in the installer window and make note of the IP address Note If you want to assign the IP manually click Assign IP This me...

Page 7: ...COM Setup select the TCP option Enter the IP address for the Host and port number 10001 is the default from above for the Port The IP address 192 168 1 100 is only an example Your IP address will var...

Page 8: ...a MultiTasker then the external power adapter must be connected Connect the power adapter to the AC301 201 If the LED is still not on see Cause 4 Cause 4 The AC301 201 has a problem Solution If there...

Reviews: