10
3 USING WITH OR WITHOUT A CARBON FILTER
Extracted air mode
The cooking air is cleaned by grease filters and is discharged outside through
ducting. (Fig. 4)
Fig. 4: Air Outlet without Carbon Filter
•
If you wish to transfer exhaust air to an inactive smoke or waste gas flue, you
must obtain authorization from a specialist.
•
Exhaust air must travel without break to an external grill or cowl.
Recirculated air mode
Cooking air is cleaned in two stages, first a grease filter and secondly an (optional)
active carbon filter. Then filtered air is transferred back to the kitchen. (Fig. 5)
Fig. 5: Air Circulation with
Carbon Filter
]
You can use this appliance in extracted air mode or recirculated air mode.
NOTICE!
Exhaust air must not be sent via an active smoke
or waste gas flue; or a flue used for ventilation of
places where heat sources are installed.
Active Carbon Filter
Discs of carbon are used in the path of airflow to
help trap and hold the substances within cooking
air responsible for bad smells.
Carbon Filters in all hoods should be changed
regularly (guide 6 months), depending on use.
Consult your local dealer or visit
www.altimo.co.uk
The model number of your hood is on the front of
these instructions. The part number for the carbon
filters required for this hood is Altimo CF002
Supplied in a pack of two (as two required)