3  USING WITH OR WITHOUT A CARBON FILTER 

 
 

 

Extracted air mode 

 
The cooking air is cleaned by grease filters and is discharged outside through 
ducting. (Fig. 4) 
 
 

 

 

   

 

 

 

Fig. 4: Air Outlet without Carbon Filter 

  

 

If you wish to transfer exhaust air to an inactive smoke or waste gas flue, you 
must obtain authorization from a specialist. 

 

Exhaust air must travel without break to an external grill or cowl. 

 
 

Recirculated air mode 

  
Cooking air is cleaned in two stages, first a grease filter and secondly an (optional) 
active carbon filter. Then filtered air is transferred back to the kitchen. (Fig. 5) 
  
 

Fig. 5: Air Circulation with  

Carbon Filter 

 


 
 
 
 
 
 
 

 

You can use this appliance in extracted air mode or recirculated air mode. 

 

NOTICE! 

Exhaust air must not be sent via an active smoke 
or waste gas flue; or a flue used for ventilation of 
places where heat sources are installed. 

 

Active Carbon Filter 

Discs of carbon are used in the path of airflow to 
help trap and hold the substances within cooking 
air responsible for bad smells. 
 
Carbon Filters in all hoods should be changed 
regularly (guide 6 months), depending on use. 
 
Consult your local dealer or visit 

www.altimo.co.uk

  

 
 

 
The model number of your hood is on the front of 
these instructions. The part number for the carbon 
filters required for this hood is Altimo CF003 
 
Supplied in a pack of two (as two required)

 

Summary of Contents for CANH601SS

Page 1: ...1 Instruction Manual 60cm Canopy Cooker Hood CANH601SS...

Page 2: ...2...

Page 3: ...NANCE 12 5 1 ALUMINIUM FILTER CLEANING 13 5 2 WASHING YOUR FILTER IN A DISHWASHER 13 5 3 WASHING YOUR FILTER BY HAND 13 6 APPLIANCE POSITIONING 14 6 1 UNPACKING THE APPLIANCE 14 6 2 ENERGY SAVING AND...

Page 4: ...4 1 TECHNICAL DRAWING Fig 1...

Page 5: ...ation is complete Make sure that the installation method allows a user to easily unplug the power cable in case of a need to isolate the unit Do not touch the lamps when they are in use as they can ge...

Page 6: ...be hermetical When connecting a flue to your product use ducting pipes with a diameter of 150mm or 120mm Minimise both the length and number of connections to the outside to promote good flow and impr...

Page 7: ...2 Fig 2 Poisoning Danger Therefore it is imperative adequate fresh air ingress is confirmed Fig 3 Fig 3 DANGER Warning Choking Hazard The packaging materials are dangerous for children Never allow ch...

Page 8: ...operate two or more gas zones longer than 15 minutes on a high flame setting A large burner over 5kW Wok has the power of two gas burners WARNING Electrocution hazard Never use a malfunctioning elect...

Page 9: ...off the unit isolate or remove the 13a plug from the socket before removing the spent bulb leave bulbs to cool down first Ensure the replacement bulb is of the same type and values CAUTION Surfaces a...

Page 10: ...kitchen Fig 5 Fig 5 Air Circulation with Carbon Filter You can use this appliance in extracted air mode or recirculated air mode NOTICE Exhaust air must not be sent via an active smoke or waste gas fl...

Page 11: ...s central motor assembly by placing the concave side towards the motor 4 One carbon filter at a time offer the filter up to its housing and rotate the filter clockwise Ensure that it is snugly fitted...

Page 12: ...Clean the metal grease filters regularly depending on usage The metal grease filters are designed to capture the greasy particles in the moisture and vapours generated when cooking It is recommended...

Page 13: ...HWASHER It is possible to wash the metal grease filter in a dishwasher This can be very effective but could lead to a slight discoloration of the aluminium over time This has no effect on the function...

Page 14: ...el cook top is 75cm The minimum distance between the bottom of the hood and an electric cook top must be at least 65cm 6 1 UNPACKING THE APPLIANCE Check over your new appliance for damage Check that y...

Page 15: ...you have adequate inlet fresh air into your room so that the cooking vapours are exited easily Start your hood on a low speed as soon as you start cooking a hood needs to work harder to clear a room...

Page 16: ...ONTENTS 1 2 3 4 5 1 Hood assembly 2 Mounting screws 3 150 120 mm Flue Adapter Optional 4 User Manual 5 Installation template 7 1 OVERVIEW OF YOUR COOKER HOOD 1 2 3 1 Hood 2 Aluminium Filter 3 Lighting...

Page 17: ...n place 7 Screw in the plastic flue adaptor assembly to the exhaust exit on the top of the hood Fig 11 a Various flue and ducting products are available you will need to adapt your installation depend...

Page 18: ...18 9 OPERATION Slider controls Fig 15 Move the slider control into the following positions to activate the function 1 Light off 2 Light on 3 No fan off 4 Fan speed 1 5 Fan speed 2 6 Fan speed 3...

Page 19: ...lamp To replace the bulb 1 Remove the aluminium grease filters 2 Remove the faulty bulb and replace with a new one with the same rating Fig 16 Fig 16 Lamp Replacement WARNING Disconnect the electrica...

Page 20: ...contact Altimo Customer Care Troubleshooting Fault description Problem area to check Remedy Product does not work Check the power connection Mains voltage must be 220 240v and plugged into an earth g...

Page 21: ...rectives This device complies with the Directive on the Control of Waste Electrical and Electronic Equipment Specifications of the device and this manual may be modified without prior notification 13...

Page 22: ...www altimo co uk For customer service call 0330 041 7490...

Reviews: