![Altimium TP70WPBH-EU User Manual Download Page 18](http://html1.mh-extra.com/html/altimium/tp70wpbh-eu/tp70wpbh-eu_user-manual_2911243018.webp)
3x1 Wallplate Transmitter Switcher with HDMI and VGA
Altimium 14 www.altimium.com
6.3.8 Button User-defined
Press the
DISPLAY ON/OFF
button can turn on/off the display. If the incompatible
display device needs to be used, the
DISPLAY ON/OFF
button can be defined to send
control characters by following the below command format.
Command
Format
Function
Command Example
/+kb: xxxx
k=0, Set the
DISPLAY ON
k=1, Set the
DISPLAY OFF
xxxx: ASCII characters
b=0, Baud rate is 2400
b=1, Baud rate is 4800
b=2, Baud rate is 9600
b=3, Baud rate is 19200
b=4, Baud rate is 38400
b=5, Baud rate is 57600
b=6, Baud rate is 115200
/+02:abc123
Set the
DISPLAY ON
to send
the ASCII characters
abc123
.
/-kb:xx xx
xx xx
k=0, Set the
DISPLAY ON
k=1, Set the
DISPLAY OFF
xx xx xx xx: HEX characters
b=0, Baud rate is 2400
b=1, Baud rate is 4800
b=2, Baud rate is 9600
b=3, Baud rate is 19200
b=4, Baud rate is 38400
b=5, Baud rate is 57600
b=6, Baud rate is 115200
/-12:30 31 32 33
Set the
DISPLAY OFF
to send
the HEX characters
30 31 32 33
.
/x0:xxx
Set the booking shutdown time to
xxx
.
SET TIME TO xxx MINUTES
TO TURN OFF THE DISPLAY IF
NO SOURCE DETECTED