4K 4x4 HDMI Matrix Switcher                                                                               

 

Altimium                                                            23                                    www.altimium.com 

 

Figure 4- 17 Password

 

In the above interface, turn on the Front Panel to lock all buttons of machine, they 
cannot be operated. 

4.3.4 TCP/IP Configuration 

IP address, subnet mask, and Gateway of MAT.HDMI44-4K can be modified via GUI 
from the above description, but beyond that users can configure the IP port, including IP 
reset, password reset, and IP module firmware update on the WebServer. 

Type the designed website (Default: 192.168.0.178:100, changeable) in your browser. 
Enter correct username and password to log in the WebServer:   

Username

: admin; 

Password

: admin 

Here is the main configuration interface of the WebServer: 

 

Figure 4- 18 TCP/IP Configuration 

4.3.5 GUI Update 

GUI for MAT.HDMI44-4K supports online update in http://192.168.0.178:100. Type the 

username and password (the same as the GUI log-in settings, modified password will 

be available only after rebooting) to log in the configuration interface. After that, click 

Return Button 

Summary of Contents for MAT.HDMI44-4K

Page 1: ...MAT HDMI44 4K 4K 4x4 HDMI Matrix Switcher All Rights Reserved Version MAT HDMI44 4K_2016V1 0 User Manual...

Page 2: ...of the trademark owner No part of this publication may be copied or reproduced without prior written consent FCC Statement This equipment generates uses and can radiate radio frequency energy and if n...

Page 3: ...ain moisture or install this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may expose...

Page 4: ...em Operations 5 4 1 IR Control 5 4 2 RS232 Control 6 4 2 1 Installation uninstallation of RS232 Control Software 6 4 2 2 Basic Settings 6 4 2 3 RS232 Communication Commands 7 4 2 4 EDID Management 12...

Page 5: ...MI Matrix Switcher Altimium www altimium com 4 4 Firmware Upgrade through USB port 24 5 Specification 26 5 1 Supported Resolution 26 6 Panel Drawing 27 7 Troubleshooting Maintenance 28 8 After sales S...

Page 6: ...l up to 4Kx2K 60Hz 1080p 3D compliant with lower HDMI standards HDCP2 2 compatible HDMI output ports support HDMI 1 4 capable to transmit 2560x1080 60Hz signal compliant with lower HDMI standards HDCP...

Page 7: ...scription Power Indicator Illuminate red when power on Turn green in standby mode Blink red when upgrading LCD Screen Display real time operation status OUTPUTS Output selection buttons press the butt...

Page 8: ...stands for On 0 stands for Off Refer to 4 4 EDID Management for more detials c RS232 Serial control port connect with control device d IR IN input port for IR control signal connect with IR receiver e...

Page 9: ...ocedure Step1 Connect HDMI sources e g DVD to HDMI INPUTs with HDMI cables Step2 Connect HDMI displays e g HDTV to HDMI OUTPUTs with HDMI cables Step3 Connect speakers amplifiers to the AUDIO OUTPUTs...

Page 10: ...nce in control and transmission the MAT HDMI44 4K can be widely used in computer realm monitoring large screen displaying conference system television education and bank securities institutions etc 4...

Page 11: ...with necessary input devices and output devices Then connect it with a PC installed RS232 control software Double click the software icon to run this software Here we take the software CommWatch exe a...

Page 12: ...r to 4 4 EDID Management for detailed information Baud rate 9600 Data bit 8 Stop bit 1 Parity bit none Command Function Feedback Example System Commands Lock Lock the front panel buttons System Locked...

Page 13: ...s for digital audio All Closed x Switch off output x 1 Closed x B y1 y2 y3 Transfer AV signal from input x to output y1 y2 y3 1B2 BlackscreenON x Switch on input x BlackscreenON1 BlackscreenOF F x Swi...

Page 14: ...ment for more details Please send the EDID file EDID x y Invoke embeded EDID data No y to input x y 1 10 y 1 10 EDID information 1 720P 2D 5 1CH 2 720P 3D 5 1CH 3 720P 2D 2CH 4 720P 3D 2CH 5 1080P 3D...

Page 15: ...lt DigitAudioON x Enable the SPDIF audio output of output x x 1 4 enable the SPDIF audio output of single output port x 9 enable the SPDIF audio output of all output ports DigitAudio ON with Output 4...

Page 16: ...9972 Inquire connection status for all outputs N means there is no display Y means there is connected display Out 1 2 3 4 Connect Y Y N N 9973 Check the inputs HDCP status N means it s not with HDCP Y...

Page 17: ...EDIDM 1 B 4 the INPUT device 1 will gain EDID data from OUTPUT device 4 Program Customized EDID data Besides 10 kinds of embedded EDID this product can program 3 kinds of customized EDID data The EDI...

Page 18: ...10 Customizable Note 1 EDID information listed in the above chart is factory default data Embedded EDID data can be updated by sending command UpgradeIntEDID x 2 Embedded EDID data can also be invoked...

Page 19: ...le to be controlled in a LAN When control just make sure the MAT HDMI44 4K s network segment is the same with the router Please connect as the following figure for LAN control Figure 4 4 Connect to LA...

Page 20: ...e MAT HDMI44 4K asynchronously Then it s able to control the device via a TCP IP communication software 4 3 2 Control MAT HDMI44 4K via TCP IP communication software Exampled by TCPUDP software 1 Conn...

Page 21: ...ium 16 www altimium com Figure 4 6 Control interface of TCPUDP Here you will receive the feedback after a command is sent Enter your command here Commands are the same with RS232 commands listed in 4...

Page 22: ...92 168 0 178 in your browser it will enter the log in interface shown as below Figure 4 7 Login GUI This system divides into administrator and user mode Administrator mode User name admin Password adm...

Page 23: ...then click Load can invoke the selected scene Click cancel to cancel the current operation 4 3 3 2 Control Menu Click Control to enter the following interface it provide intuitive I O connection switc...

Page 24: ...t OUTPUT column If all OUTPUT ports in needed you only need to click All Step3 Choose a scene that you want to save Step4 Click Confirm to save the setting or Click Clear to clear set up 4 3 3 3 Confi...

Page 25: ...t to copy its EDID Step2 Select one or more input devices that need to gain EDID When select To All inputs all input devices will copy the EDID from output device Step3 Click Confirm to save the setti...

Page 26: ...interface to modify the name and mode of this machine and then they will be display in LCD screen Figure 4 13 Status LCD 2 Select Button to enter the following interface to modify the name of buttons...

Page 27: ...Network to enter the following interface to inquire and configure network settings including MAC address IP address subnet mask and Gateway Figure 4 16 Network 5 Password At the top of the interface...

Page 28: ...t and IP module firmware update on the WebServer Type the designed website Default 192 168 0 178 100 changeable in your browser Enter correct username and password to log in the WebServer Username adm...

Page 29: ...opy the upgrade software DfuSe Demonstration upgrade file dfu to control PC Steps to upgrade the device Step1 Connect the control PC to the USB port of MAT HDMI44 4K Step2 Reboot MAT HDMI44 4K to ente...

Page 30: ...com Figure 4 21 Upgrade firmware via DfuSe Demonstration Step4 Click Choose to load desired upgrade file dfu Step5 Click Upgrade to start Make sure the button Leave DFU mode is available to ensure con...

Page 31: ...Dolby Digital DTS DTS HD Max Resolution 4Kx2K 1080P 3D Transmission Distance 4Kx2K 60Hz 15m Power Supply DC 12V 2A Power Consumption 13 3W Full Load 4 4W Standby Dimension W H D 436 x 44 x 235 mm Weig...

Page 32: ...4K 4x4 HDMI Matrix Switcher Altimium 27 www altimium com 6 Panel Drawing 44 mm 436 mm 23 mm 32 mm SYSTEM MONITOR OUTPUTS POWER 1 2 3 4 MAT HDMI44 4K...

Page 33: ...CP compliance status The display doesn t support the input resolution Switch for another input source or enable the display to learn the EDID data of the input No output on the amplifiers connected to...

Page 34: ...rough RS232 port Wrong connection Check to ensure the connection between the control device and the unit Wrong RS232 communication parameters Type in correct RS232 communication parameters Baud rate 9...

Page 35: ...een altered or removed from the product Damage deterioration or malfunction caused by Normal wear and tear Use of supplies or parts not meeting our specifications No certificate or invoice as the proo...

Page 36: ...ALTIMIUM 587 Avenue Blaise Pascal 77550 MOISSY CRAMAYEL T l 01 64 13 31 00 Fax 01 60 29 62 70 Mail contact tesca audio com Web www altimium com...