3 Technical Description
This single axis, industrial tilt measuring system, which consists of one none-contact sensor and an
electronic customized for said sensor, serves to measure accurate tilt angles in x-axis and is intended
for side wall mounting. The range of the angle to measure can be set by an internal dip-switch. The
measured values are put out digitally via a RS232 interface. With version …-420-… these values can
also be read out via standard 4 … 20 mA analogue output.
The measuring system is contained a robust aluminum die cast enclosure which is perfectly suited for
rough industrial environment.
4 Terminal Assignment
The electrical connection (Unitronic FD CP plus 3x2x0,25mm²) has been made via EMC cable glands and
soldered inside. The length varies, depending on the version. The shield of the cable is connected to the
housing.
Clamp
Description
Color
1
Supply voltage
white
2
GND Supply voltage
brown
3
RS232-interface (9600 Baud, 8N1)
pink
4
External control signal for tare / zero*
grey
5
GND Analogue output
green
6
Analogue output 4…20 mA
yellow
EMC-Cable-gland
Shield
Cable shield/blank
*In order to tare the read-out, put 24V on pin 4. It is to be secured against unintentional operation.
4.1 Supply Voltage
The supply voltage can be 22 … 26 VDC. An external Fuse of SI
extern
=200mA
is necessary.
4.2 Measuring value output RS-232
The measured values are put out constantly via the RS-232-interface (9600 Baud, 8N1) with a
sampling rate of approx. 2 per second and may be displayed and recorded with a terminal-application
like HyperTerminal for Windows
®
for
example.
4.2.1 Measuring value output 4 … 20 mA
In case of version …-420-… the tilt angle can be read out via the analogue output of 4 … 20 mA. For
scaling please refer to page "Device-Configuration".”. Max. impedance is 500 Ohms.
Scaling (example -see next page):
-10° …
0
…
+10°
4
…
12
…
20 mA