6 Maintenance 

The flawless function and calibration of the whole measuring system is to be checked regularly. This 
inspection  is  also  necessary  after  every  repair  or  change  of  any  component  of  the  measurement 
system. 



7 Old appliances disposal 

 

According to European and German law, it is prohibited to dispose of old electronic 
devices into household waste, but must be collected and disposed of separately. 

 

Amplifiers  and  measurement  units  manufactured  and  sold  by  Althen  Mess-  &  Sensortechnik  GmbH 
serve B2B purposes only. Therefore, those old appliances must not be given to the communal disposer, 
but must be given back to the seller or disposed of properly. If you need any further information, please 
contact your local authorities. 

These  measures  serve  to  protect  the  environment  and  allow  recycling  and  recovery  of  valuable 
materials.  Furthermore,  do  electronic  devices  contain  substances  that  may  cause  damage  to  the 
environment if burned or dumped with normal household waste. 

 

 

 

Summary of Contents for NM1 4L Series

Page 1: ...ance Althen DB Innovation Tél 0033 0 4 67 78 61 66 info althensensors fr Sweden Althen Sensors Control AB Tel 46 0 8 7 95 24 90 info althensensors de USA Canada Altheris Inc Sensors Controls Inc Tel 1 858 633 3572 info althensensors com Other Countries please contact us by email at sales althensensors com www althen de V2 1 eng 1 2 Axis Tilt Measuring System NM1 NM2 4L ...

Page 2: ...t 6 4 1 Supply voltage 7 4 2 Galvanic isolation 7 4 3 Analogue Outputs 7 5 Starting up 8 5 1 Description od measuring axis 9 5 2 Calibration of the tilt measuring system 11 5 3 Zero point adjustment 11 5 4 Adjustment calibration of the amplifier 11 5 5 Calculation tilt angle 12 6 Maintenance 13 7 Old appliances disposal 13 Appendix 14 Datasheet 14 Order Designation 14 EMC mounting 16 Datasheet Acc...

Page 3: ... complete measuring unit must be protected against contact and influence of unauthorized persons In the case of a safety relevant application where a potential malfunction could cause damage to property or persons it is imperative that an additional independent monitor is provided In combination with sensors the maximum loads pressures etc must never be exceeded If you have reasons to assume that ...

Page 4: ...sensor shields correctly To avoid possible potential equalization currents over the shield of the cable to the following evaluation unit this shield should be connected over a suitable capacitor 10 nF 200 V Overall the shield connections must be done properly to EMC standards as short as possible with large wire cross section and connected to a central point star grounding In order to not increase...

Page 5: ...e than 3 Megaohms The on board tilt sensor type AccuStar is supplied with an internal voltage of 10 V The output signal has a ground reference With a tilt of 0 degrees the output signal of the sensor is 2 5 V The signal which is 33 mV per degree tilt is amplified to an analogue output of either 0 10 Volt 10 Volt 0 20 mA or 4 20 mA The system supply voltage is galvanically isolated from the interna...

Page 6: ...ection is 2 5 mm The EMC installation instruction is to be complied with NM1 IP 4L 12E 24E Clamp Description 1 Supply voltage Ub 2 GND operating voltage Galvanic isolation 3 Analogue output 4 GND analogue output NM2 IP 4L 12E 24E Description 1 Operating voltage Ub 2 GND operating voltage Galvanic Isolation 3 Analogue output y axis 4 GND analogue output 5 Analogue output x axis 6 GND analogue outpu...

Page 7: ...dditional fuse is necessary is to be considered However an additional external fuse of SIextern 0 4 A slow is recommended 4 2 Galvanic isolation The supply voltage of the amplifier is galvanically isolated from analogue output sensor supply and sensor signal To unset this isolation just bridge clamp 2 and 4 resp 6 4 3 Analogue Outputs According to your order the following analogue outputs are avai...

Page 8: ...cked 8 In order to accomplish the EMC and IP 65 protection the lid is to be closed carefully right after the initial start up NM2 IP 4L 12E 24E 1 The measuring system is to be leveled horizontally 2 The tilt measuring system is to be mounted to a horizontal surface on the object The mounting holes are visible after remove of the lid 3 Connect the tilt measuring system according to the terminal ass...

Page 9: ...tput 4 GND analaogue Output Zero point potentiometer Sensor Control LEDs 2x green Aluminum enclosure Protection class IP65 Version 010 Version B10 Version 420 0 Volt 5 Volt 10 Volt 10 Volt 0 Volt 10 Volt 0 mA 10 mA 20 mA Scaling of analogue output Axis Notice The enclosure is to be mounted on an grounded machine part Version 020 4 mA 12 mA 20 mA ...

Page 10: ...ps 1 Supply Voltage 2 Comm galvanic isolation 3 Analogue Output y axis 4 GND analaogue Output 5 Analogue Output x axis 6 GND analogue output Sensor y axis Sensor x axis Zero Point potentiometer y axis Control LEDs 2x green Scaling analogue output Scaling analogue output X AXIS Y AXIS Zero Point potentiometer x axis M16 EMC Cable Gland Version 010 Version B10 Version 420 Version 020 Measuringaxis ...

Page 11: ... help of e g precision spirit level 3 Now adjust the zero point according to the table below Version Analogue Output Zero point NM1 NM2 IP 4L 010 0 10 Volts 5 V NM1 NM2 IP 4L B10 10 Volts 0 V NM1 NM2 IP 4L 020 0 20 mA 10 mA NM1 NM2 IP 4L 420 4 20 mA 12 mA Notice If the maximum zero point adjustment range of 1 5 degrees should not be sufficient a remounting is to be considered 5 4 Adjustment calibr...

Page 12: ...0 Analogue Output 5 V defined angle full range x 5 V Version B10 Analogue Output defined angle full range x 10 V Version 420 Analogue Output 12 mA defined angle full range x 8 mA Version 020 Analogue Output 10 mA defined angle full range x 10 mA ...

Page 13: ...isposed of separately Amplifiers and measurement units manufactured and sold by Althen Mess Sensortechnik GmbH serve B2B purposes only Therefore those old appliances must not be given to the communal disposer but must be given back to the seller or disposed of properly If you need any further information please contact your local authorities These measures serve to protect the environment and allo...

Page 14: ...ion on internal extension spring Enclosure EMC aluminum pressure enclosure IP66 Dimensions W x H x D NM1 175x80x57 NM2 160x160x91 Weight NM1 ca 1000g NM2 ca 2300g Storage temperature range 20 C 60 C Operating temperature range 20 C 60 C Order Designation NM1 IP 4L NM2 IP 4L 1 axis tilt measuring system 2 axis tilt measuring system 12E 24E Operating voltage 10 18 VDC Operating voltage 18 30 VDC 010...

Page 15: ...15 20 Housing Dimensions NM1 NM2 ...

Page 16: ...reen Use with cable screen Connect screen to ground with a ground clamp Amplifier Sensor Grounding case Case need to be mounted on a grounded surface 1st Step 2nd Step 3rd Step Skin cable Lay open the braid Lead cable through cap nut Establish cable in clamping put braid over clamping Braid have to overlap the o ring approx 2mm Put clamping application in Cable gland Tighten cap nut FINISHED ...

Page 17: ...17 20 Datasheet Accustar ...

Page 18: ...18 20 ...

Page 19: ...19 20 ...

Page 20: ...20 20 Subject to modifications All information describe our products in general form ...

Reviews: