Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices
8–9
Configuration
May 2013
Altera Corporation
1
Smaller Cyclone IV E devices or package options (E144 and F256 packages) do not
have the
MSEL[3]
pin. The AS Fast POR configuration scheme at 3.0- or 2.5-V
configuration voltage standard and the AP configuration scheme are not supported in
Cyclone IV E devices without the
MSEL[3]
pin. To configure these devices with other
supported configuration schemes, select
MSEL[2..0]
pins according to the
MSEL
settings in
.
JTAG-based configuration
—
—
(1) Configuration voltage standard applied to the V
CCIO
supply of the bank in which the configuration pins reside.
(2) JTAG-based configuration takes precedence over other configuration schemes, which means the
MSEL
pin settings are ignored.
(3) Do not leave the
MSEL
pins floating. Connect them to V
CCA
or GND. These pins support the non-JTAG configuration scheme used in production.
Altera recommends connecting the
MSEL
pins to GND if your device is only using JTAG configuration.
Table 8–4. Configuration Schemes for Cyclone IV GX Devices (EP4CGX30 [only for F484 package], EP4CGX50,
EP4CGX75, EP4CGX110, and EP4CGX150) (Part 2 of 2)
Configuration Scheme
MSEL3
MSEL2
MSEL1
MSEL0
POR Delay
Configuration Voltage Standard (V)
(1)
Table 8–5. Configuration Schemes for Cyclone IV E Devices
Configuration Scheme
MSEL3
MSEL2
MSEL1
MSEL0
POR Delay
Configuration Voltage Standard (V)
AS
1
1
0
1
Fast
3.3
0
1
0
0
Fast
3.0, 2.5
0
0
1
0
Standard
3.3
0
0
1
1
Standard
3.0, 2.5
AP
0
1
0
1
Fast
3.3
0
1
1
0
Fast
1.8
0
1
1
1
Standard
3.3
1
0
1
1
Standard
3.0, 2.5
1
0
0
0
Standard
1.8
PS
1
1
0
0
Fast
3.3, 3.0, 2.5
0
0
0
0
Standard
3.3, 3.0, 2.5
FPP
1
1
1
0
Fast
3.3, 3.0, 2.5
1
1
1
1
Fast
1.8, 1.5
JTAG-based configuration
—
—
(1) Configuration voltage standard applied to the V
CCIO
supply of the bank in which the configuration pins reside.
(2) JTAG-based configuration takes precedence over other configuration schemes, which means the
MSEL
pin settings are ignored.
(3) Do not leave the
MSEL
pins floating. Connect them to V
CCA
or GND. These pins support the non-JTAG configuration scheme used in production.
Altera recommends connecting the
MSEL
pins to GND if your device is only using JTAG configuration.
Summary of Contents for Cyclone IV
Page 10: ...x Chapter Revision Dates Cyclone IV Device Handbook March 2016 Altera Corporation Volume 1...
Page 14: ...I 2 Section I Device Core Cyclone IV Device Handbook March 2016 Altera Corporation Volume 1...
Page 274: ...vi Contents Cyclone IV Device Handbook February 2015 Altera Corporation Volume 2...
Page 440: ...iv Contents Cyclone IV Device Handbook December 2016 Altera Corporation Volume 3...
Page 442: ...vi Chapter Revision Dates Cyclone IV Device Handbook December 2016 Altera Corporation Volume 3...
Page 446: ......