page 30
of 35
File: SM1180_r9eng - December 2007 - Technical note: SM1180 & TM 060
SM
1180 & TM060
File: SM1180_r9eng - December 2007 - Technical note: SM 1180 & TM 060
page 31
SM1180 & TM060
Wiring example
Page 1: ...SM1180 TM060 SWITCHING POWER GENERATOR FOR 6 KW MAGNETRON SM1180 D for line 3 x 208V SM1180 T for line 3 x 400V SM1180 U for line 3 x 480V TM060 generator head TECHNICAL NOTE issue December 2007...
Page 2: ...Al quale questa dichiarazione si riferisce conforme alle seguenti norme complies with the following norms EN 61010 1 2001 EN55011 1999 EN55011 A1 2000 EN55011 A2 2003 The D version complies also the...
Page 3: ...e 2002 SM1180T3_r2eng 3 Deleted TM060 version 3 May 2004 SM1180T3_r3eng 4 Upgraded with SM1180U data October 2004 SM1180_r4eng 5 Upgraded with RD8400 data September 2005 SM1180_r5eng 6 Upgraded with S...
Page 4: ...and products now Cr VI is used as anticorrosion layer on aluminium part We are evaluating alternative coating It is still present within the limit of 0 1 in weight as set by Directive Lead it is larg...
Page 5: ...s appliance must be installed and serviced only by qualified personnel The appliance must only be used by persons acquainted with the regulations covering the application Note about EMC regulation the...
Page 6: ...utput power or the alarms codes a 4 digit display lower showing the reverse power if the necessary external accessories are provided several signalling LED for working conditions inlet air filter The...
Page 7: ...the internal circuits and components then it goes out from the rear panel The intake air flow is approx 200 m h The rear panel comprises the following a 7 pins socket for main supply Conn 1 the fuses...
Page 8: ...control section of the SM1180 vers 54 55 Two 6A fuses F1 and F2 are provided to protect the 230V nominal circuit A max current of 1 4 Arms 230V must be provided in normal operation while 3 2 Arms is...
Page 9: ...Humidity 80 for temperature up 31 C 88 F decreasing linearly to 50 RH at 40 C 104 F Pollution degree 2 according IEC664 Physical characteristics Standard dimensions 19 x 7HE 482x311 mm Rack total widt...
Page 10: ...lbs for SM1180D U Always lift from the bottom and use an adeguate rugged support to avoid personal injury and damage to equipment itself In case of shipping package with wooden case and a proper fill...
Page 11: ...hree poles breaker and must comply the norm EN61010 1 XII the external circuit breaker must be in close proximity to the SM1180 and within easy reach of the operator XIII the external circuit breaker...
Page 12: ...case of magnetron overtempe rature WATCH DOG OFF with no alarms FLASHING in case of arc detection an electrical arc occured inside the waveguide launcher and has been detected by the arc detector ON...
Page 13: ...t n 2 pin n 12 bit n 3 MSB pin n 13 Buttons meaning and programming procedures Master CPU During normal operation the display shows a user defined parameter In addition the on board software allows th...
Page 14: ...ay will show F_nn you are now at step II VII Press F and hold for 2 second to exit from the program ming mode and to go to current page You may exit at any time if none value has been modified the pre...
Page 15: ...ON F_03 till F_12 Not used F_13 Internal use don t modify F_14 Internal use don t modify F_15 Not used F_16 X1 Coordinate for linearization of la It affects the la value displayed F_17 Y1 Coordinate...
Page 16: ...d F_07 600 6000W Reverse Power alarm threshold F_8 80 Not used F_9 8000 Not used F_10 1 Not used F_11 0 Not used F_12 0 Working hours counter F_13 0 EEPROM initialization value 1 F_14 0 EEPROM initial...
Page 17: ...h dry air reinstall cover tighten all the screws plug the connector 1 push the plug into the socket rotate clockwise the ring Fuses replacement To replace the fuses on rear panel proceed as follow swi...
Page 18: ...g g 14 5 Female pin size III CPCX 1630881 g g g 15 1 7 pins Plug AMP CPC CPC07 2114001 g g g 16 5 Male pin size III CPCX 1630861 g g g 17 1 9 pins Socket AMP CPC Conn 4 CPC09 2067051 g g g 18 9 Female...
Page 19: ...oke 42 FI1180A BT c g g 40 1 H V Choke 42 FI1180A AT c g g 41 1 H V Transformer 42 FT1180A c g c 1 H V Transformer 42 FT1180U c c g 1 H V Transformer 42 FT1180DA g c c 42 1 2 Pins socket PHOENIX MSTB2...
Page 20: ...File SM1180_r9eng December 2007 Technical note SM 1180 TM 060 page 19 of 35 SM1180 TM060 Components layout...
Page 21: ...page 20 of 35 File SM1180_r9eng December 2007 Technical note SM1180 TM 060 SM1180 TM060 Pin out of connector 1 SM1180D v 4 5...
Page 22: ...File SM1180_r9eng December 2007 Technical note SM 1180 TM 060 page 21 of 35 SM1180 TM060 Pin out of connector 1 SM1180T U v 4 5...
Page 23: ...page 22 of 35 File SM1180_r9eng December 2007 Technical note SM1180 TM 060 SM1180 TM060 Pin out of connector 1 7 SM1180D v 54 55...
Page 24: ...File SM1180_r9eng December 2007 Technical note SM 1180 TM 060 page 23 of 35 SM1180 TM060 Pin out of connector 1 7 SM1180T U v 54 55...
Page 25: ...page 24 of 35 File SM1180_r9eng December 2007 Technical note SM1180 TM 060 SM1180 TM060 Pin out of connector 2...
Page 26: ...File SM1180_r9eng December 2007 Technical note SM 1180 TM 060 page 25 of 35 SM1180 TM060 Pin out of connector 3 and 5...
Page 27: ...page 26 of 35 File SM1180_r9eng December 2007 Technical note SM1180 TM 060 SM1180 TM060 Pin out of connector 4 using Linear Power Sensor RD8400Ax...
Page 28: ...lament voltage Warning When ENABLE is on don t operate on filament as it is at High Voltage to ground Il Trimmer RS1 permette la regola zione fine della tensione di filamento ruotando in senso orario...
Page 29: ...or wiring waveguide inside and magnetron antenna for damage A__4 Overcurrent Undercurrent Anode current is 20 more than maximum Check magnetron H V connections and insulation Reference voltage is lowe...
Page 30: ...nge style PDR26 magnetron type YJ1600 B or C water and air cooled output power 6 kW 2 45 GHz arc detector fitted on waveguide air pressure switch water flow switch white lamp on panel lighted up when...
Page 31: ...page 30 of 35 File SM1180_r9eng December 2007 Technical note SM1180 TM 060 SM1180 TM060...
Page 32: ...File SM1180_r9eng December 2007 Technical note SM 1180 TM 060 page 31 of 35 SM1180 TM060 Wiring example...
Page 33: ...page 32 of 35 File SM1180_r9eng December 2007 Technical note SM1180 TM 060 SM1180 TM060 Assembling example with circulator...
Page 34: ...eral models available ask for quote and type Cable set p n 441384084 full set single side plugs SM p n 441384085 full set double side plugs SMv0 3 TMv0 p n 441384089 full set double side plugs SMv0 3...
Page 35: ...Vcc Outputs 1 or 2 not correlated Error at frequency sweep 50MHz 1 max Different attenuation value for each channel yes Mechanical characteristics Dimensions 173x130x45 mm Weight 0 5 kg Protection IP...
Page 36: ...of the RF modulated input signal 3 Average Power jumper between pin 4 and 6 of D type connector the output is the mean value of the modulated input signal The graph shows the behaviour of the output s...