Installation Instructions for 6”Arm:
1. Remove the cover of the 6” arm bracket.
2. Be certain the support pole has adequate mounting surface and conforms to code
3. Determine whether to store the wire connections in the cable access cavity [*] or in the pole
interior
4. Open cable-access plate, safely store the tiny screws.
5. With the pole and its mounting holes set at the desired height, bring the lamp and bracket
arm up to be mounted.
6. Support the backing plate inside the pole, aligned precisely with the mounting holes.
7. Support the luminaire arm near the mounting holes and thread power cable through the
largest hole of the sealing gasket, through the pole’s largest drilled hole, and through the
backing plate’s hole.
8. Feed the three Allen 6mm bolts through to the backing plate to set their screws hand tight.
Then fully tighten the middle bolt, followed by the upper bolt, then the lower bolt.
9. Connect the input and ground wires of the fixture to the power supply. Brown is live. Blue is
neutral. Green/Yellow is ground.
10. Re-fasten cover plate.
11. Enclose the open pole top and seal as necessary
6/6