background image

°C

-5~5

11

AD2

Temp. sensor 2 adjustment

ALTEC

PV

Out

ON

OFF

ON/OFF  Control  -  Cooling  mode

ON/OFF  Control  -  Heating  mode

L1

KY1

PV

Out

ON

OFF

L1

KY1

Technical Data

While temperature sensor connection breakdown 

VR

 is displayed, or while overrange 

SNB

 is displayed.

At this time, when the temperature sensor T1 fails, relay output(OUT) is determined 

by 

PF1

 as shown in the parameter list.

6.6 Sensor Failure

Switch off the controller; press keys ▲ and ▼ at the same time and hold on, then 

switch  the  controller  on  again.  Parameter 

SPK

  appears  on  display.  Parameter 

selection  and  the  display  of  the  value  is  obtained  by  pressing  key  P  repeatedly; 

change with keys ▲ and ▼ and store with S.

6.4

 

Parameter List

SPK

Mnemonic

Setpoint high limit

Parameter

-50

~150

°C

°C

Adjustable Range

limit the adjustable range of 

L1

 

and 

AL2

Parameter

 

Description

5

SN

SPL

-50

~150

°C

°C

6

0~10

 

minutes

Compressor protection

7

RT1

OUT relay min. off 
time

Setpoint low limit

AT1

Output action

D,R
REV

Direct(cool)
Reverse(heat)

10

°C

-5~5

9

AD1

Temp. sensor 1 adjustment

PF1

Temperature sensor 
failure output

ON
0FF

OUT 'ON' while sensor failure
OUT 'OFF' while sensor failure

8

1

L  1

Temp. differential setpoint

SPK

~

SPL

2

KY 1

Hysteresis 1

10 °C

1~

Operation parameter

3

AL2

Alarm value

SPK

~

SPL

4

KY2

Alarm hysteresis

10 °C

1~

2AL

Alarm object

T1
T2
DT

Channel 1 measured temp. T1
Channel 2 measured temp. T2
Temperature difference

12

6.3 Output Action

AT1

 = 

D,R

, OUT1 as cooling control output;

AT1

 = 

REV

, OUT1 as heating control output;

While  the  controller  was  configured  for  cooling  applications,  to  avoid  compressor 

switch  off  and  on  frequently,  must  set  the  minimum  off  time 

RT1

  between  the  switch 

OFF and switch ON, regardless of the input value.

The control algorithm is ON/OFF, temperature differential setpoint is 

L1

, hysteresis is 

KY1

.

WWW.ALTEC.CC

Sample rate

Measurement range

Resolution

Temperature sensor

Relay contact rating

Control algorithm

Power supply

Environmental

-50~150  °C

1  °C

NTC,  PVC  Wire,  2.0m

5(8)A/250VAC

125ms

ON/OFF

220V AC, 

2.0W

Temp:  -20~55  °C

,

Rel.  Humidity

:

85%

Dimensions

W78

H35

D78mm

×

×

ALO

Alarm mode

0FF
K,A
LOA

Turn alarm off
Full-scale high alarm
Full-scale low alarm

13

6.5

 

Alarms

Full-scale high alarm(

K ,A

)

Full-scale low alarm(

LOA

)

AL2

AL2

Alarm  LED

PV

time

Hysteresis 

KY2

Alarm  LED

PV

time

Hysteresis 

KY2

Two  different  types  of  alarm  can  be  configured  with 

ALO

K  ,A

and 

LOA

  as  the  right 

table

 

shows. The alarm h

is 

KY2

.

H

  is  used  to  provide  a  definite  indication  of  the  alarm  condition  and  to 

prevent alarm  relay chatter.

 

ysteresis 

ysteresis