9.4 Measuring Voltage at the Power Line Filter
9.4.1
Remove the Top Cover (section 8.11 ).
9.4.2
Locate the Power
Line
Filter inside the Top Section
of the air dryer.
9.4.3
Use a Voltmeter to measure
the voltage:
9.4.3.1
Place the probes
between the Power Line
Filter and terminal
insulation so that they
touch the metal
contacts.
The voltage should measure:
110 - 125 VAC
for the P4200W & P4200WLP models.
220 - 230 VAC
for the P4202W & P4202WLP models.
If any of the voltage measurements are different than indicated above, the Power
Line Filter is defective and should be replaced. See sections 11.1 for part detail
and 11.7 for ordering information.
9.4.4
Reinstall the Top Cover (section 8.11 ).
WARNING!
Extreme care should be exercised to avoid contact with live
electrical circuits.
It is highly recommended that you remove all
jewelry before performing any procedures.