BYK-Gardner
byko-drive S
285 025 845 E 2106
11
The factory stored settings are as follows:
1.
Speed - 100mm/sec, Length - 235mm, Offset - 0mm
2.
Speed - 200mm/sec, Length - 215mm, Offset - 20mm
3.
Speed - 450mm/hr, Length - 235mm, Offset - 0mm
(drying time setup)
4.
Speed - 1.0 in/sec, Length - 9.2 in, Offset - 0 in
5.
Speed - 7.9 in/sec, Length - 9.2 in, Offset - 0 in
6.
Speed - 5.0 in/sec, Length - 8.5 in, Offset - 0.7 in
System Setup
Press the
Tool
icon in the upper right corner of the home screen to access the
Setup
screen. Note the current settings. Press the band you wish to change and
it will turn blue. Press once more to access the screen to change the setting.
Note that once you start making changes to the settings, the
Preset
you are
changing will change from yellow to blue with a white ring. This is to remind
you of the preset that is being changed. You do not have to save the changes if
you want to make a temporary change. If not saved, the changes made will be
lost if the unit is turned off or another preset is selected. To save the changes,
press and hold the button where you would like to store the settings for at
least 3 seconds. When you release the button it will be yellow and the settings
will be stored and able to be recalled on the run screen by pressing the appro-
priate
Preset
button.