DISTRIBUTION AMPLIFIER/ZONE MIXER/MIC SPLITTER DA-410.
Distribution amplifier/zone mixer/mic splitter set up to 230 V.
Distribution amplifier/zone mixer/mic splitter set up to 115 V.
Make sure that the fuse is the right one for the selected voltage:
FUSE (230V. 50-60 Hz) FUSE (115V. 50-60 Hz)
T0,5A.
T1A.
CHANGING THE FUSE
The distribution amplifier/zone mixer/mic splitter unit is set to operate at 230V, 50-60Hz or at
115V, 50-60Hz.
Make sure that the unit is disconnected from the mains.
In the unit rear panel, is placed the mains connector and the fuse holder. The box bellow this
mains connector is called fuse holder. Take out the fuse holder.
Upon extracting the fuse holder, the fuse will appear, take out it and change for the new one.
Insert the fuse holder into the mains connector again.
NOTE:
The fuseholder provide a place for spare fuse.
CAUTION:
Always make sure upon changing the fuse, that this is the adequate for the selected
mains voltage (T1A for 115V and T0,5A for 230V).