20
DISTRIBUTION AMPLIFIER/ZONE MIXER/MIC SPLITTER DA-410.
OUTPUT
TRANSFORMER POSITION
LINKS TO REMOVE
OUT 1L (1)
TR5
LK9 and LK10
OUT 1R (2)
TR6
LK11 and LK12
OUT 2L (3)
TR7
LK13 and LK14
OUT 2R (4)
TR8
LK15 and LK16
OUT 3L (5)
TR9
LK17 and LK18
OUT 3R (6)
TR10
LK19 and LK20
OUT 4L (7)
TR11
LK21 and LK22
OUT 4R (8)
TR12
LK23 and LK24
OUT 5L (9)
TR13
LK25 and LK26
OUT 5R (10)
TR14
LK27 and LK28
In the following picture is showing the placement of the output transformer TR5
corresponding to the OUT 1L (1) output. It is important to keep in mind the placement of the output
transformer pins so that they coincide with the main board (seven to the top and six to the bottom).
Remove the links corresponding to the output transformer. In this
case LK9 and LK10.
Place the output transformer, keeping in mind the
position of their pins (seven to the top and six to the
bottom), and solder it to the main board.
EQUALISER CARD
Two equaliser cards connectors are provided per output. Next table explains
the correspondence between the affected output and the labelled insert connector
as appears in the main distribution amplifier PCB.
EQUALISER CARD INSERT CONNECTORS
OUT 1L
(1)
OUT 1R
(2)
OUT 2L
(3)
OUT 2R
(4)
OUT 3L
(5)
OUT 3R
(6)
OUT 4L
(7)
OUT 4R
(8)
OUT 5L
(9)
OUT 5R
(10)
J1, J2
J3, J4
J7, J8
J10, J11
J12, J13
J15, J16
J17, J18
J21, J22 J23, J24
J26, J27
When the eq card is not installed, the signal path must be closed with a jumper.
Keep in mind this circumstance whenever you change, update or place for the first time an
equaliser card. Of course, in order to insert the equaliser card, you should remove the connector
jumper in which you want to place the equaliser card.