background image

Riga #207

72 

3-pc deckmount tub filler with handshower / r

obinet de bain 3mcx avec douchette

 

alt

-aqua.com

Riga #207

72 

3-pc deckmount tub filler with handshower / r

obinet de bain 3mcx avec douchette

 

alt

-aqua.com

5

2

3

4

1

INSTALLATION

4

6

7

8

5

3

2

1

Fig.2

Fig.3

1.

Installing the Spout

Prior to installation, pierce the required 3 holes
onto your deckmount. Refer to Fig.1 for hole size.

         

To faciliate future maintenance, ensure 

access to to rough-in.

Remove the Allen setscrew (2) and pull out the faucet 
body (1) from the shank (5). (see Fig.2)

Unscrew the top nut (4) from the shank (5).
Insert the shank body through the hole from under-
neath
the deck and tighten with nut (4) from the top (Fig.3).
If needed, also tighten bottom nut (8) with metal (7) 
and
rubber (6) washer from beneath the deck.

Finalise the spout installation by inserting it back into 
the shank and securing it with Allen setscrew (2).

Installation du bec 

Avant de débuter l’installation, percer les 3 trous 
requis sur la surface prévue. Se référer à Fig.1 pour 
la dimension des trous.

         Pour faciliter l’entretien futur, assurer un accès 
au brute du robinet

Dévisser la vis de retenue Allen (2) et séparer le bec (1)
de son raccord (5). (voir Fig.2)

Dévisser l’écrou de retenue (4) du haut du raccord (5).
Ensuite, insérer le raccord par en dessous de la surface 
et remettre l’écrou de retenue (4) par le haut. S’assurer 
de fixer le raccord fermement (Fig.3). Au besoin, serrer 
également l’écrou du bas (8) avec les rondelles en 
caoutchouc (6) et en métal (7).

Finaliser l’installation du bec en l’insérant à nouveau 
dans le raccord et en revissant la vis de retenue 
Allen (2).

GENERAL DIMENSIONS 

DIMENSIONS GÉNÉRALES

BEFORE YOU START

AVANT DE COMMENCER

      

 CAUTION: FOR BEST RESULTS, WE STRONGLY 

RECOMMEND THE INSTALLATION OF THIS FAUCET BE 
DONE BY A LICENSED PROFESSIONAL PLUMBER.

       

CAUTION: MAKE SURE TO PROPERLY FLUSH THE 

HOT AND COLD WATER SUPPLY LINES PRIOR TO START-
ING INSTALLATION.

Required tools

- Adjustable wrench
- Phillips screwdriver

       

MISE EN GARDE:  POUR OBTENIR UN RÉSULTAT 

OPTIMAL, NOUS RECOMMANDONS FORTEMENT QUE 
L’INSTALLATION DE CE ROBINET SOIT FAITE PAR UN 
PLOMBIER PROFESSIONNEL ACCRÉDITÉ.

       

MISE EN GARDE: ASSUREZ-VOUS DE BIEN 

PURGER LES CONDUITS D’ALIMENTATION D’EAU 
CHAUDE & FROIDE AVANT DE COMMENCER 
L’INSTALLATION.

Outils requis

- Clé à molette
- Tournevis à tête Phillips

[113.00]

4 3/8”

[54.00]

2 1/8”

[143.50]

5 5/8”

[54.00]

2 1/8”

[49.50]

1 61/64”

max [38.00]

1 1/2”

[219.00]

8 5/8”

[54.00]

2 1/8”

[26.00]

1 1/32”

[244.50]

9 5/8”

[105.00]

4 1/8”

[173.42]

6 13/16”

Reviews: