6. 

Installing / dismantling the controller  

a. 

TFT panel 

 

Ensure that the power is turned off ! 

 

Cable for connecting the controller should be derived from the wall – preferably, it is mounted in a typical box as 
electrical equipment (power sockets, switches .... etc.) 

 

Next, drill two holes in the wall for wall plugs, symmetrically to the can. These holes should be done horizontally with 
ce of 89mm. 

 
 
 

 

 

 

 

 

 

 

      
    

WALL BOX 

 

 

 

 

 

 
 

 

 

 

 
 
 
 
 

 

 

 

 

 

     89 mm 

 

 

 
 
 

 

control panel case consists of two halves, connected to the latch. You must gently divide them. You can help yourself 
with a flat screwdriver, undermining the special holes in the cover (bottom left or top right corner of the housing). 

 

Mount to the wall with screws. 

 

The cable should be connected to the upper half of the housing containing the electronics controller. Excess cable 
should be put in a box in the wall. 

 

The cable mustn't be shortened or extended!

 

 

 

Connect gently upper and lower half. 

 
 

b. 

The relay module 

 

Installation and wiring must be carried out with power off! 

 

Diagrams are supplied separately. 

 

The module should be mounted in a recuperator or as close as possible so that the fan power cables are as short as 
possible. 

 

To connect wires use screwdriver type philips PH0 

 

The recuperator power supply must be protected with appropriate fuse. 

 

The electrical connection should be made by person with the appropriate permissions. 

 
 
To dismantling controller to pieces use screwdriver PH0 and to separate TFT from pcb use hot air desolder. 
 
NOTE !!!

 – Connecting should be done carefully and accurately according to the scheme. Connect the adequate colors in the 

appropriate connector line in the module relays. Different connection from the schema can cause damage to the driver!  
 
Figure below shows the arrangement of colors used in the supplied cable UTP 
 

 
 
 

 

   

ORANGE

 

 

 

max. lenght 10m 

 

         

ORANGE

 

  

 

        

GREEN 

 

 

 

 

 

              GREEN

 

 
 
 
 

 

            BLUE 

 

 

 

 

 

              BLUE 

 

 

     BROWN 

 

 

 

 

 

              BROWN 

 

 
 

 

 
 

NOTE !!!

 – color name on PCB Polish = English 

 

BRAZOWY = BROWN 

 

NIEBIESKI = BLUE 

 

ZIELONY = GREEN 

 

POMARANCZ = ORANGE 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for MSR-20

Page 1: ...set of rotation 2 in english ver icon name is rot shortphrase of rotation displaying the shortened information about current configurations sets 3 switching to controller s configuration mode 4 2 Manu...

Page 2: ...e following functions escape the same function as the Esc computer button the minus value decreasing the value of the edited parameter the plus value increasing the value of the edited parameter appro...

Page 3: ...to normal operation If you press the switch again during this operation it will cause the break of the procedure and earlier return to normal mode mode 3 Fire protection fan SUPL STOP fan EXH MAX This...

Page 4: ...eat exchanger Mode OFF the procedure is totally off and system doesn t react for any signal This solution can be use in case that the recuperator is provided with internal defrosting system for ex sup...

Page 5: ...request It allows to connect the controller to the BMS network by WiFi To set or read parameters controller use 0x03 Read Holding Register 0x06 Write Single Register and 0x10 Write Multiple Registers...

Page 6: ...nnect gently upper and lower half b The relay module Installation and wiring must be carried out with power off Diagrams are supplied separately The module should be mounted in a recuperator or as clo...

Page 7: ...ller can be received by the customer or sent to the client without the cost of transport service will repair it within 14 working days this period may be extended with the time that is taken to bring...

Reviews: