alres MSR-20 Manual Download Page 3

 

GHE

 – the configuration of the Ground Heat Exchanger. The edition is the same as for clock case. 

 

 

 

config : 

OFF

 - total turning valve GHE off. The air always taken from the external inlet 

 

config : 

ON

  - the valve is always turned on for taking the air from GHE regardless of temperatures 

 

config : 

AUTO 

– the valve is controlled basing on the temperatures measurementsTo and Tg and Comfort settings 

 

config : 

AUTO R 

– the same as above with the additional option of GHE regeneration 

 

comfort : 

HEATING

  – selecting warmer power source with the air (usually autumn, winter) 

 

comfort  : 

COOLING 

 – selecting cooler power (usually spring, summer) 

 

comfort  : 

TEMP To 

– automatic work depends on outside temperature 

 

 
 

 

BYPASS

 – the configuration of bypass. Edition is the same as other functions before. 

 

 

 

config : 

OFF

 - total turning the bypass valve off. The air always comes through the exchanger 

 

config : 

ON

  - the valve is always on. The air always bypasses the exchanger. 

 

config : 

AUTO

 – the valve is controlled basing on the temperatures measurements. Te, To, Tg 

 

Tout > …°C

  - to turn the bypass on, the power temperature Has to be above that value – it is the air temperature of 

the external inlet sensor or GHE sensor, depending on the previous setting mode. The range of the setting is [5÷20°C] 

 

Textr >…°C – 

as above, the extract air from the room must be bigger than that value. The range is [15÷30°C] 

 
 

 

DIGITAL INPUT (CFG) 

 – controller has an input, market on the relay board as WE5. To this input we can connect Any 

floating switch such as a relay output of fire protection system, alarm, etc… This option lets you determine how controller should 
respond to the appearance of the signal in input. Mode's changes, as in the previous edition. You can choose one out of seven (the 
last one is reserved for the water heater HW protection). 

 

mode 1 – 

Inactive

. Controller does not respond to this input signal. 

 

mode 2 – 

High Vent, 

fans = MAX

. The option can be used for short-term switch to maximum speed for the intensive 

ventilation of rooms such as kitchen, bathroom... To control in this mode you should use monostable switch such as 
bell switch type. Pressing the switch will cause that controller sets fans to maximum speed for 30 minutes. After this 
time the controller will return to normal operation. If you press the switch again during this operation it will cause the 
break of the procedure and earlier return to normal mode. 

 

mode 3 – 

Fire protection

, fan SUPL=STOP fan EXH=MAX

. This mode is intended to cooperate with the fire 

protection instalation. When the signal is on WE5 the controller turns off supply air fan and exhaust fan switches to the 
maximum speed until the signal from a fire protect. system does not change state. 

 

mode 4

 

– 

Stand by

, fans = MIN

. Configuration that can work with home alarm (security) systems. Arming the alarm 

system during the absence of occupants, make controller go into the minimum air exchange. 

 
 
 

 

SCHEDULE

 – this option allows to programme various ventilator' speeds, suitably for the individuals' needs. In this way for 

the every hours of any other day there are various speeds' values. After selecting the "schedule" icon, the controller changes the 
main menu screen for the table consisting of graphic presentation of particular configuration. The current value in accordance with 
the data and time is highlighted in green. Edition is the same as for the clock. During the edition the values are changed for the 
yellow colour. 
 
 

 

FAN SPEED

 – [they are a active only for EC fans] Function allows to ascribe particular speeds to particular gears of 

ventilation. Given values [%] match the value of output voltage. The range of permissible values is 10% ÷ 100%. Nevertheless, one 
has to remember that 0-10% value is considered as a STOP. So that the general range is bigger than that. During selecting 
particular speeds, the controller automatically controls in the way that setting the gear with the bigger number has got bigger 
percentage than previous one. The edition is the same as above. 
 

 

 
 
 
 
 
 
 
 

 

mode 5 – 

PRESOSTAT

 If the recuperator is equipped with a pressure switch which measures the pressure drop 

across the filters, the contacts can be connected to this input. This will provide a maximum information about usage 
degree of filters. 

 

mode 6 – 

SPEED++ humidistat

 It can be connected to WE5. After exceeding a certain value of humidity, the 

controller will increase fan speed by one degree. If the humidistat continues giving a signal after about 20 minutes the 
controller automatically will increase fan speed for the next step. This will remain until the signal disappears from 
humidistat or if will remain max speed. 

 

mode 7 – 

Thermostat

  protection against heater damage 

Summary of Contents for MSR-20

Page 1: ...set of rotation 2 in english ver icon name is rot shortphrase of rotation displaying the shortened information about current configurations sets 3 switching to controller s configuration mode 4 2 Manu...

Page 2: ...e following functions escape the same function as the Esc computer button the minus value decreasing the value of the edited parameter the plus value increasing the value of the edited parameter appro...

Page 3: ...to normal operation If you press the switch again during this operation it will cause the break of the procedure and earlier return to normal mode mode 3 Fire protection fan SUPL STOP fan EXH MAX This...

Page 4: ...eat exchanger Mode OFF the procedure is totally off and system doesn t react for any signal This solution can be use in case that the recuperator is provided with internal defrosting system for ex sup...

Page 5: ...request It allows to connect the controller to the BMS network by WiFi To set or read parameters controller use 0x03 Read Holding Register 0x06 Write Single Register and 0x10 Write Multiple Registers...

Page 6: ...nnect gently upper and lower half b The relay module Installation and wiring must be carried out with power off Diagrams are supplied separately The module should be mounted in a recuperator or as clo...

Page 7: ...ller can be received by the customer or sent to the client without the cost of transport service will repair it within 14 working days this period may be extended with the time that is taken to bring...

Reviews: