Backlit Braille Waterproof Keypad
AS-ATP2S200
Read all instructions before starting installation
Drill mounting using template provided.
Connect keypad using wiring description.
For 12vDC inductive loads such as electric strikes and
electromagnetic locks, the enclosed 12vDC metal oxide
varistor must be connected in parallel with the load, at
the load terminals and not in the keypad.
Ensure power supply is of correct rating, taking into
account the current requirements of the locking items and
accessories.
Do not insert security plugs into fixing holes until all
installation and testing has been completed. These items
require drilling out and cannot be re-fitted.
Wiring description
Brown
Power Supply Inputs
12-24v AC/DC, 1.3W
Blue
Power Supply Inputs
12-24v AC/DC, 1.3W
Grey
Relay common
Yellow
Relay N.C.
Green N.O.
White/Pink Remote opening door
(DRY CONTACT ONLY)
LED signalling explanation
BLUE LED
Default lighting
GREEN LED Door Strike activated
RED LED
Normal Operation:
3 seconds ON = wrong code entry
Slow flashing = wrong code entry 3
times
RED LED
Programming Mode: Fast flashing = programming different
functions
Slow flashing = programming stand-by
Very fast flashing = erasing all user
codes
Apply power
to the keypad. The keypad’s buzzer will sound briefly, the
Red LED will illuminate briefly. Initialisation is now complete, with a default
master code of 1-2-3-4 and a 5-second open door.
MOUNTING INSTRUCTIONS
ACTIVATION
TESTING THE UNIT
PROGRAMMING THE KEYPAD
TROUBLE SHOOTING
INITIALISATION
Pink
Brown
+
White
Blue
-
Grey
Commom
To
Negative
of Lock
To Positive
of Fail
Secure
Lock
To Positive
of Fail
Safe Lock
Yellow
N.C.
Green
N.O.
Exit Button
Enter the master code [1 2 3 4 #]
The Door Relay changes its contacts for 5 sec.
The Green LED will light up for 5 sec. Repeat this step 2,3 times.
If the master code is wrongly typed in, the Red LED lights up for 3 sec. re-
enter the Code as soon as the LED goes OFF.
IMPORTANT: CHANGE THE FACTORY SET MASTER CODE WHEN YOU
PROGRAM YOUR UNIT FOR USE. THERE IS NO WAY TO RECOVER THE NEW
MASTER CODE IF IT IS LOST OR FORGOTTEN. THE UNIT CAN BE RESET TO
FACTORY PRESETS AND CUSTOMISED AGAIN. See Data Reset
Enter
H H
1 2 3 4
H H
The keypad enters programming mode, the Red LED flashes.
If no further
information is added, the unit will revert to normal operation after a 12
second delay. To exit programming press #.
There are 8 programming options:
1. Set new master code
It is suggested the Master Code is not changed until person programming
is familiar with all aspects of programming the keypad!
2. Set new user code
3. Erase a user code
4. Erase all user codes
5. Set door open time (1-99s)
6. Set door output to latch option
7. Set ‘remote opening’ time (1-99s)
8. Set ‘remote opening’ to latch option
The keypad does not “respond” when activating the keys.
1. Make sure the electronic unit has been properly wired to the PSU and the
power has not been cut-off.
The keypad “responds” but the door does not open.
1. Make sure the Green LED is illuminated.
2. If not, the entered code has not been programmed yet. Please refer to
“Programming”.
3. Enter the Master Code and make sure the door opens correctly. If not,
check the wiring and the Lock’s integrity.
Continued over...
Power
Supply
Unit
Break
Glass