Backlit Braille Waterproof Keypad

AS-ATP2S200

Read all instructions before starting installation

Drill mounting using template provided.
Connect keypad using wiring description.
For 12vDC inductive loads such as electric strikes and 

electromagnetic locks, the enclosed 12vDC metal oxide 

varistor must be connected in parallel with the load, at 

the load terminals and not in the keypad.
Ensure power supply is of correct rating, taking into 

account the current requirements of the locking items and 

accessories.
Do not insert security plugs into fixing holes until all 

installation and testing has been completed. These items 

require drilling out and cannot be re-fitted.

Wiring description

Brown 

Power Supply Inputs

 

12-24v AC/DC, 1.3W

Blue  

Power Supply Inputs

 

12-24v AC/DC, 1.3W

Grey 

Relay common

Yellow 

Relay N.C.

Green N.O.
White/Pink  Remote opening door
 

(DRY CONTACT ONLY)

LED signalling explanation

BLUE LED 

Default lighting

GREEN LED  Door Strike activated 
RED LED 

Normal Operation: 

3 seconds ON = wrong code entry

 

 

Slow flashing = wrong code entry 3 

  

times

RED LED  

Programming Mode:  Fast flashing = programming different 

  

functions

 

 

Slow flashing = programming stand-by

 

 

Very fast flashing = erasing all user 

  

codes

Apply power

 to the keypad. The keypad’s buzzer will sound briefly, the 

Red LED will illuminate briefly. Initialisation is now complete, with a default 

master code of 1-2-3-4 and a 5-second open door.

MOUNTING INSTRUCTIONS

ACTIVATION

TESTING THE UNIT

PROGRAMMING THE KEYPAD

TROUBLE SHOOTING

INITIALISATION

Pink

Brown

+

White

Blue

-

Grey

Commom

To 

Negative

of Lock

To Positive 

of Fail 

Secure 

Lock

To Positive 

of Fail

Safe Lock

Yellow

N.C.

Green

N.O.

Exit Button

Enter the master code [1 2 3 4 #]

The Door Relay changes its contacts for 5 sec.

The Green LED will light up for 5 sec. Repeat this step 2,3 times.

If the master code is wrongly typed in, the Red LED lights up for 3 sec. re-

enter the Code as soon as the LED goes OFF.

IMPORTANT: CHANGE THE FACTORY SET MASTER CODE WHEN YOU 

PROGRAM YOUR UNIT FOR USE. THERE IS NO WAY TO RECOVER THE NEW 

MASTER CODE IF IT IS LOST OR FORGOTTEN. THE UNIT CAN BE RESET TO 

FACTORY PRESETS AND CUSTOMISED AGAIN. See Data Reset

Enter

  

H H

1 2 3 4 

H H

The keypad enters programming mode, the Red LED flashes. 

If no further 

information is added, the unit will revert to normal operation after a 12 

second delay. To exit programming press #.

There are 8 programming options:

1. Set new master code

It is suggested the Master Code is not changed until person programming 

is familiar with all aspects of programming the keypad!

2. Set new user code
3. Erase a user code
4. Erase all user codes
5. Set door open time (1-99s)
6. Set door output to latch option
7. Set ‘remote opening’ time (1-99s)
8. Set ‘remote opening’ to latch option

The keypad does not “respond” when activating the keys.
1.  Make sure the electronic unit has been properly wired to the PSU and the 

power has not been cut-off.

The keypad “responds” but the door does not open.
1.  Make sure the Green LED is illuminated.
2.  If not, the entered code has not been programmed yet. Please refer to 

“Programming”.

3.  Enter the Master Code and make sure the door opens correctly. If not, 

check the wiring and the Lock’s integrity.