2
Alpine SE42 Direct Vent Gas Fireplace
GENERAL INFORMATION
Listed:
D
IRECT VE
NT
GA
S F
IREPL
ACE
HEA
T
E
R
Tested to
:
AN
SI Z2
1.88
a-
20
03
/CSA
2.33
a-
200
3
V
E
NTE
D
G
A
S
FIREPL
ACE
HEA
TER.
Rep
ort
N
o.
30
609
53
(J
un
.0
4)
DO
NOT
RE
MOVE THIS
LABEL
Serial Number: SERRANO
SE42-
PROP
AN
E : S
E
RRAN
O
S
E
42
-L
P
M
inim
um
supply
pr
essur
e
11”
W
C
M
anifold pr
essur
e high
10.
0”
W
C
M
anifold pr
essur
e low
6.
4”
W
C
Orif
ice Size
# 50
DMS
M
inim
um
input
31,
000
BT
U/h
M
axim
um
input
38,
000
BT
U/h
Altitude
2500 – 6500
Ft
NAT
UR
AL G
A
S
: SERRA
N
O
SE
42
-N
G
M
inim
um
supply
pr
essur
e
4.
5”
W
C
M
anifold pr
essur
e high
3.
5”
W
C
M
anifold pr
essur
e low
2.
2”
W
C
Orif
ice Size
# 32
DMS
M
inim
um
input
32,
000
BT
U/h
M
axim
um
input
41,
500
BT
U/h
Altitude
2500 – 6500
Ft
Model SE42-LP
Model SE42-NG
Use Only
Sim
pson Dur
a-
V
ent GS System
. Use only
Sim
pson vent cap
#0991 on
ver
tical ap
plications.
T
his appliance
m
ust be
instal
led in accordance
with the
m
anufactur
er
’s
installation instr
uctions and with local codes,
if any
; if
not,
follow the cur
re
nt ANSI
Z223.
1 in the
USA.
This vented gas fireplace heater is not for use with
air filters.
El
ectric
al
supply
120VAC,
3.
5 Am
ps, 60Hz.
T
his appliance is
only
for
use with the ty
pe
of gas indicated on the r
ating plate and
m
ay be installed
in an after
m
ar
ket, per
m
anently loca
ted
m
anufactur
ed ho
m
e (
U
SA only)
or
m
obile ho
m
e,
where not pr
ohibite
d by
local codes.
See owner
’s
m
anual for
details. This applia
nc
e is not conver
tible
for
use with other
gases,
unless a cer
tified kit is used.
T
his appliance appr
oved for
bedr
oo
m
installations.
VENTED
G
A
S FI
REPLA
C
E
HEATER
NOT FOR
USE
WITH
SOLID FUEL.
Alpine
Gas Fir
eplac
es
Lehi, Utah
Mad
e in
US
A
Fie
ld C
onve
rte
d
Put L
abe
l H
ere
This applia
nce must
be insta
lled in
accordance
with the following
minimum clearances
:
2” t
o com
bust
ibl
es
– T
op
1/
2” t
o c
om
bus
tib
le
s –
Si
des
1” t
o com
bust
ibl
es
– B
ack
0” t
o com
bust
ibl
es
– B
ot
to
m
22
” fro
m
to
p
of stov
e
– Ceiling
28
” fro
m
to
p
of stov
e-Ceilin
g (flex
)
6” t
o c
om
bust
ib
le
M
ant
el
pr
oject
in
g
6”
fr
om
wal
l.
A
dd 1” o
f hei
ght
fo
r
ev
ery
1”
of
p
ro
ject
io
n a
ft
er t
he
6”
m
inim
um
.
Flue clear
anc
es are
as
follows:
Horiz
ontal Pi
pe
2” t
o c
om
bust
ib
le
s
– T
op
1”
t
o c
om
bust
ib
le
s –
Si
des
1/
2”
to
co
m
bustib
les –
B
ottom
1 1/
2”
Clear
ance to
Vertic
al Pipe
This applianc
e may
be rec
essed until
the
fro
n
t o
f
th
e uni
t is
flus
h w
ith
an
y
co
mb
us
tib
le
fa
cing
mat
er
ia
l. No
n
combustibles may overl
ap.