2.2  Calling from LLW 

The  functionality  of  NLLW  is  influenced  by  connection  of  further  lift 

components  (failure  notification,  relay,...)  as  same  as    by  setting  of  NLLW 
parametres (via. chapter 4 

– P / page24). 

2.2.1 Emergency call  (button activation) 

The  emergency  call  is  basic  and  most  important  feature  of  NLLW.  It  is 

activated by  button pressing (screw BTN). To provide correct functionality  you 
must keep 2 conditions:  

First  condition

  is  that  ,  button  blocking  is  not  active.  Please  note  that 

blocking  might  be  either  by  leading  voltage  5-24V  or  by  disconnection  this 
voltage. 

Second  condition

  is  that  button  you  must  hold  enough  time.  It  is 

adjustable from  0,5 sec to 5 sec. 

Button  pressing  has  priority  before  other  calls  (service,  failure  even 

incoming).  If  is  being  a  call  (  not  emergency)  the  call  is  stoped  and  starts 
emergency call procedure.  

 
During  emergency  call  is  active  both  way  voice  communication.  During 

establishing  call  is  lighting  yellow  indicator  .  After  call  connection 

–  call 

confirmation 

– green indicator light up. 

Emergency call dial progressivelly stored numbers 

(1÷6 position). It starts 

from  position  1  up  to  position  which  is  not  programmed.  It  means  when  you 
programm  numbers  to  all  6  position  then  progressivelly  dial  all  6  numbers. 
When  you  erase  number  on  position  3  then  dial  numbers  on  position  1  and  2 
and  returns  back  to  position  1.  You  can  also  programm  how  many  times  the 
round  (programmed  numbers  on  position  1-6  should  be  repeated  (  1  to  5 
times). While is emergency call the button does not react on other pressing and 
even more any other stage might not break emergency call procedure.  

The  machine  room  call  only  can  break  emergency  call  (chapter  2.2.6 

page.21).  The  last  point  of  emergency  call  is  call  confirmation  .  At  every 
emergency number ( position 1-6) you can select confirmation or not. (chapter 
2.2.5 

– page.20.). Dialling is stoped after call connection.  

2.2.2 Calling from  INPUT  - Failure call 

Calling  from  activated  input  INPUT  is  named  failure  calling  -  set 

parameter 

391

.  The  NLLW  enables  to  make  notification  about  lift  failure  for 

service  department.  The  call  is  activated  by  voltage  change  (  5-24V  ON/OFF) 
on  input  INPUT.  It  is  adjustable  in  setting.  As  follow  you  can  select  time  how 
long must be change on input INPUT to start failure calling. 

Failure  calling  has  own  number    which  might  be  of  course  the  same  as 

emergency  or  service  call  number.  You  can  also  select  if  will  be  dialling  only 
this  number  or  all  round  of  emergeny  numbers  (  then  you  have  max  7 
numbers) .   

Summary of Contents for New Link Lift Watch 50

Page 1: ...ALPHATECH TECHNOLOGIES s r o Jeremenkova 88 Praha 4 Czech Republic www alphatechtechnologies cz New Link Lift Watch Lift communicator User guide...

Page 2: ...er PC via configuration software For connection the NLLW to PC you have to use special cabel After button pressing the NLLW enables to make phone call up 6 numbers max 16 digits in tone or pulse dial...

Page 3: ...2 CALLING FROM LLW 19 2 2 1 Emergency call button activation 19 2 2 2 Calling from INPUT Failure call 19 2 2 3 Calling from INPUT Technical call 20 2 2 4 Service calling from timer 20 2 2 5 End of cal...

Page 4: ...2 24V second mode is using only if you haven t power supply then you use power for current loop from telephone line CAUTION It is not galvanically isolated Third mode is external power for example but...

Page 5: ...room call it is calling between lift cabin and machine room Incoming call it is calling coming from outside into NLLW unit The NLLW pick up you can programm parametres Dial it is kind of dial on telep...

Page 6: ...uring TRH setting that incoming direction speaker and outgoing direction microphone are influence each other We recommend to dont set high volume in the begining of micro or speaker and via TRH set bo...

Page 7: ...s possible choice from the current loop is powered Attention button is galvanic connect with source power of current loop and isolated from line by optocoupler In case powered current loop from teleph...

Page 8: ...into loudspeaker Level from which volume with switch on direction from microphone doorphone setting trimmer TRH This setting interact level surrounding noise and setting gain of microphone MIC Progre...

Page 9: ...voltage in Hang up status disconnect loop 20 60V during connection not depends on polarity when NLLW pick up active status on telephone line is cca 7 12V depends on line current which is in range 20...

Page 10: ...e 10 1 3 5 Button and blocking connection BUTTON a BLOCK When telephone line is connected we need connect button only The button is connected to screw terminal mark BUTTON Look on picture 4 Picture 4...

Page 11: ...ton is galvanic connect with source power of current loop and isolated from line by optocoupler In case powered current loop from telephone line is button galvanic connect with telephone line Picture...

Page 12: ...puts for those indicators are isolated from other components and each from other as well The switchers are made until current 0 5A and voltage 50V On Picture 6 you can see examples of lamp indicator c...

Page 13: ...of this voltage change before failure calling is activated INPUT is possible connecting up to 100m and is possible conecting moore butons switch on paralel or switch off buttons serial Control of type...

Page 14: ...8 Connection of machine room communication 3WR When use in machine room modul PREPOJ you can see on picture 8 its connection From machine room to lift cabin must lead 3 wires Picture 8 Connection of m...

Page 15: ...powering power 12 24V is possible and DC or AC voltage because telephone line has not enough power Screw 12V is isolated from other components and not depends on polarity Screw marks COM is share outp...

Page 16: ...e 16 1 4 NLLW Installation The compact solution of NLLW enables easy installation into lift cabin panel Dimension and installation holes are descriped on picture 10 SPK MIC panel NLLW unit Picture 10...

Page 17: ...three SPK MIC panels The lift cabin panel should be equiped by acoustic holes in microphone as same as speaker part It should be also provides by 4 screws M4 for fixing the SPK MIC panel The proper m...

Page 18: ...lighting Command confirmation from phone 425 Dial DTMF Pulse Light off Call lighting x Notification of call ending 1275 lighting x Enter to programming mode from phone 850 Yellow lighting Programming...

Page 19: ...ed It means when you programm numbers to all 6 position then progressivelly dial all 6 numbers When you erase number on position 3 then dial numbers on position 1 and 2 and returns back to position 1...

Page 20: ...mber or all round of emergeny numbers then you have max 7 numbers The service calling is repeated in period 0 9 min programmable until succesfull call confirmation The repeated time between calls is p...

Page 21: ...on box named PREPOJ and via connection of third wire telephone line has 2 wires And third is for NLLW controlling Wires connection is displayed on picture 8 page 15 The call is activated by picking up...

Page 22: ...ametres The initial state for programming is signaled by programming tone and the guard will come back to this state always after time expiration 5 seconds even you started to program anything When pr...

Page 23: ...line powering Procedure Connect the NLLW to the line Connect the NLLW with PC by KAB cable if PC serial port absent the USB COM reduction is to be used The NLLW will answer and LED light on the front...

Page 24: ...Note Default 21 t nn Number nn in order p with confirmation t t call confirmation programm 0 1 only 0 confirmation OFF nn telephone number up 16 digits To programm other characters look on table Basi...

Page 25: ...ers programmed in parameter 21 and 1 List of corresponding parametres 1 21 31 56 36 Parameter Value Note Default 33 i For failure calling are used also emergency numbers 0 i 0 emergency numbers are no...

Page 26: ...position until empty or 6th position This is 1 sequence It might be repeated max 5 times List of corresponding parametres 1 Parameter Value Note Default 38 e Time of failure duration before failure c...

Page 27: ...rameter Value Note Default 45 yyyyyy Confirmation character during dial in advance 66 yyyyyy confirmation character is numerals combination from 2 to 6 numerals List of corresponding parametres 1 21 2...

Page 28: ...p always between rings It is 2 seconds after detection q th rings The number is adjustable from 1 to 9 List of corresponding parametres 44 Parameter Value Note Default 52 d Max call duration 2 d max t...

Page 29: ...ks up the line and dialling the number range 1 5 sec This time is different for each PBX type but usually all PBXs works with time up 2 seconds List of corresponding parametres 8 85 Parameter Value No...

Page 30: ...duration time ms range 1 0 it is 60 150ms m the time of space between tones is calculate insert number 5 x 10 space duration time ms range 1 0 it is 60 150ms f the time of Flash is calculate insert n...

Page 31: ...ting for parametres 5x only 5 only Parameter 81 perform erasing of all numbers saved in memories of emergency service and failure call Parametres 83 85 perform selected default for parametres 3 5 only...

Page 32: ...ng is switched off z 1 only tones pick up and hang up z 2 only other tones except pick up and hang up z 3 all tones they are switched on Parameter Value Note Default Ex 1 Ex 2 6 p polarity input buton...

Page 33: ...cy call sequences 1 38 e The failure time duration before activation of failure calling 1 39 w Failure error call or Technical call 1 41 v Dial type v tone pulse 0 42 z Character to prolong a call 43...

Page 34: ...rametres 5x only 5 only 9 E N D 5 Technical parametres 5 1 Elektrical parametres Parameter Value Conditions Min line current 18mA Line OFF HOOK Min line voltage 18V Line ON HOOK Line voltage when is N...

Page 35: ...6 Emergency number position 3 Confirm 1 0 13 16 Emergency number position 4 Confirm 1 0 14 16 Emergency number position 5 Confirm 1 0 15 16 Emergency number position 6 Confirm 1 0 16 16 Service call n...

Page 36: ...for relay switching from phone 48 2 Time of relay closing 49 2 Number of rings before picks up 51 1 Max call duration min 52 1 Time of button holding sec 53 1 Hanging up time when is redial sec 54 1 T...

Page 37: ...Picture 11 Example of connection with LED blocking and failure is activated by voltage connection machine room communication...

Page 38: ...TECHNOLOGIES s r o Jeremenkova 88 140 00 Praha 4 Czech Republic VAT CZ27577350 Company is registered in the Commercial Register administered by the Municipal Court in Prague Section C Record 116886 Ba...

Reviews: