User and service manual 39
This constant serves a purpose to identify the no.1 button in the composition of
the module. After entering the number of buttons
s
the button no 1 is moving so
it is always first.
Number of buttons on the main panel
s - choice
1
1
2
2
4
4
WARNING !!
setting this parameter materially affects number dialling.
Parameter
Value
Meaning
Basic
6*
t
Delayed start for switchboards with line
testing (Siemens) (0/1)
0
This function is off as standard
t=0
. By switching this function on
t=1
the
processor goes into sleep mode immediately after the line connection, and after
3 secs. The Brave initialises. The line connection after the power supply
connection is then delayed - state switching on/restarting of the switchboard. If
this function is not working and the telephone switchboard still identifies a line
fault, then there is no other option but to use :
BestBox (external module)
mudule SlimKeyboard (include permanent power doorphone from 12V)
Parameter
Value Meaning
Basic
6#
s
Setting of the number of buttons on the main
panel.
2