BRAVE SlimDP
–
User and service manual 35
Parameter
Value
Meaning
Basic
503
tt
Tone length of time for DTMF (tone) choice
(04-16)
10 (100ms)
504
mm
Time of gap between DTMF tones
(04-16)
10 (100ms)
505
f
Length of flash time (1-6)
1 (100ms)
506
p
Length of time of pause/digit gap (1-0)
4 (800ms)
tt
Length of DTFM tone choices is specified by the formulae:
(the entered number) x 10 = time length of tone
[ms]
[range 04-16 which is 40-160ms]
m
Length of gap between DTMF tone choices is specified by the formulae:
(the entered number) x 10 = time length of gap
[ms]
[range 04-16 which is 40-160ms]
f
L
ength of flash is specified by the formulae:
the entered number x 100 = time length Flash
[ms]
[range 1-6 which is 100-600ms]
p
L
ength of pause is specified by the formulae:
the entered number x 100 + 400 = time length of pause
[ms]
[range 1-0 which is 500-1400ms]
Time
p
is the simultaneously length of gap between button taps for an
impulse choice.
Parameter
Value
Meaning
Basic
507
uu
Transmit level of DTMF choice v [-dBm]
(04-16)
10
uu
Transmission level of (DTMF) choice to the line, the range is -4 to -
16dBm, input the required level where uu=04 is -4dBm, uu=10 is -10dBm