10
We reserve the right to modify technical specifications without prior notice.
83063900cUK – Translation of the operating manual
© ait-deutschland GmbH
“Dimensional drawings” and “Clearance
dimensions” overviews.
Proceed as follows at the installation location:
ATTENTION
Set unit on a solid and level, preferably sound-in-
sulated surface.
Mount feet…
ATTENTION
Moving the unit without the feet mounted can
damage the floor.
Mount the feet
before
installing the module box
in the unit.
Proceed as follows to mount the feet on the unit:
•
Tip the unit slowly and carefully to one side.
Secure unit in raised tilted position so that it cannot
accidentally tip back into the original position.
CAUTION!
Hands and fingers could be crushed during
the following tasks!
•
Mount one foot each on the front and back of the
unit.
1 Foot
2 Lock nut
3 Adjusting screw
Transport unit to installation location using a hand
truck or have two persons carry it.
ATTENTION
Do not damage the hydraulic connections under
any circumstances.
–
Push hand truck only beneath back of unit for
transport.
NOTE.
Without the module box, the unit can be trans-
ported horizontally.
1 Recessed grips
2 Carrying strap
ATTENTION
Never use components and hydraulic connec-
tions on the unit for purposes of transport.
INSTALLATION
WARNING!
Several people are required to install the
unit. Do not underestimate the weight of
the unit.
NOTE.
The heat source can be connected either on the
left or right side of the unit. Maintain the re-
quired clearance between the connection side
and the wall.
“Installation of the hydraulic connections”,
“Connection of module box to the heat source”
section.
ATTENTION
Always comply with required clearance dimensi-
ons.
Summary of Contents for WZS 41-101H/SX