041-028-B0-003, Rev. C
21
5.0
Engine Shut-Down and Cable Removal, continued
5.4 Fuse
Replacement
Tools and Materials Needed:
•
10mm and 8mm socket
• Ratchet
handle
• Torque
wrench
•
Replacement fuse: Alpha P/N 460-273-10, Hinode Electric Co. P/N 350GH-80
Procedure:
1. Set the ENGINE SW to OFF. Disconnect the extension
cable from the DC Out jack.
2. Remove the four 10mm nuts from the front plastic housing,
and remove the housing.
5. Remove the two 10mm nuts holding the fuse onto the fuse
holder. When reassembling, carefully tighten nuts to the
following torque specifi cations:
3.2 to 6.4 N m
2.4 to 4.7 ft-lbs.
28 to 56 in-lbs.
6. Replace fuse, and reassemble the generator in reverse
order.
3. Locate the fuse cover below the OUTPUT SW.
4. Remove the two 8mm bolts on the bottom of the fuse cover.
Remove the cover.
Summary of Contents for DCX3000
Page 2: ...Power Alpha Technologies...
Page 23: ......