IA543

 

 

Intercom Amplifier

 

Installation & Configuration Manual 

 

The Alpha Communications® IA543 Intercom Amplifier is designed to allow two-way communications between 
an open voice lobby panel and multiple apartments. Additional equipment will allow communications with 
multiple entrance panels. Entrance panels will signal up to an apartment by pressing the corresponding call 
button, and the resident can answer using

 

TALK

 

and 

LISTEN

 

buttons. A  

DOOR

 button provided on the 

apartment station can be configured to operate an electric door strike or magnetic lock to allow visitor entry. 

 

The IA543 is compatible with additional equipment to provide specialized applications and features such as 
hearing impaired strobe lights, multiple sequenced door operations, integration into access control systems, 
and Postal locks.

 

 

 

INSTALLATION PROCEDURE 

 

Read this manual to insure proper wiring, component placement, and installation methods.  
 

WIRING REQUIREMENTS 

 
Depending on the facility layout and number of apartments, inside stations may be connected by risers 
comprised of common wires with selective wires from each inside location, or connected in a home run 
method from each inside location. Apartment stations can be of the 3, 4, or 5 wire varieties and can be used in 
combination if necessary. 
 

 

 

 

 
 
 

Alpha Communications®   42 Central Drive   Farmingdale, NY 11735-1202 

Toll Free: 1-800-666-4800 Phone: 631-777-5500  Fax: 631-777-5599 

Website: 

www.AlphaCommunications.com

   Email: [email protected] 

 

 

Copyright© 2010-2017AWD142 Alpha Communications® All Rights Reserved.

                   

AWD143

 Rev. 3

 

(01/2018) 

Please note: Terminal identifications in this manual may not be shown in the actual order that 

they appear on the equipment. 

Summary of Contents for IA543

Page 1: ...operations integration into access control systems and Postal locks INSTALLATION PROCEDURE Read this manual to insure proper wiring component placement and installation methods WIRING REQUIREMENTS De...

Page 2: ...a heavier gauge wire to reduce voltage drop ENTRY PANEL S Mount all entry panels in a suitable location protected from harsh weather and water Although many panels are weather resistant the more prot...

Page 3: ...door strike when the inside station DOOR Button is pressed while also supplying 16VAC for system power Pay special attention to the transformer wiring and terminal markings The length of activation ti...

Page 4: ...hat proper polarity between the magnetic lock and its power supply is observed The length of door release time is determined by the dipswitch settings approx 2 10 or 25 seconds USING THE PK407A ISOLAT...

Page 5: ...allow the Postal Lock to release the door for 25 seconds independent of the 1 2 setting works only with 4 wire stations Dipswitch 6 when OFF will only allow the door to release for the time determine...

Page 6: ...or Voice Volume and Tone Volume located through two access holes on the front cover Use a small screwdriver and do not use excessive force Carefully turn clockwise to increase the volume High volume s...

Page 7: ...7...

Page 8: ...ive visual indication notification enabling efficient operation of a busy office Wall or desk mounted master stations available in White Titanium or Brown Can be used to indicate room status emergency...

Reviews: