Installation Instructions

KIT CONTENTS

1.

GENERAL

Note: These flues MUST ONLY be used with the Alpha Condensing boilers.

a.

The Alpha Easy-Flue is suitable for straight horizontal flues only and can be extended up to the maximum lengths
given in Section 4.

b.

The Alpha CD Easy-Flue is suitable for providing two options for management of the exhaust flue gas/plume emitted
from the terminal. They are:-
i. Divert the plume at 45° by altering the terminal of the the Easy-Flue.
ii. Extend the inner flue duct by using Plume Management accessories to re-locate the terminal to an area where the

plume will not cause a nuisance. 

Note: 

When fitting plume management accessories, ensure there is always a

slope towards the Easy-Flue assembly in the wall by a minimum of 25-30 mm per metre and there is no part of the
pipework where condensate/rain will collect.

Refer to Section 5 for full details.

c.

The Easy-Flue includes a 90° bend, (no separate 90° bend is required).

d.

Ensure the Easy-Flue outer duct is installed horizontally (please note that the Easy-Flue inner duct already has a pre-
determined slope towards the boiler for condensate to run back towards the boiler) and when extending the flue with flue
extensions, these flue extensions must be installed with a slope downwards towards the boiler by a minimum of 25-30
mm per metre.

e.

The flue system must be installed in accordance with BS 5440:1.

f.

The boiler must be installed in accordance with the installation instructions supplied with the Alpha condensing boiler.

g.

The CD Easy-Flues are suitable for use in the flue length ranges shown in the tables below.

Note: 

Where the length is less than the minimum or more than the maximum, refer to Section 4.

Alpha CD Easy-Flue

(with Plume Management Facility)

CD Easy-Flue 500 mm Part No. 6.2000510
CD Easy-Flue 1000 mm Part No. 6.2001010

Fig. 1 - Rear Flue

CD50 Boiler

CD Easy-Flue

500 mm

1000 mm

B (mm)

Max

440

885

Min

230

675

HE Boiler

CD Easy-Flue

500 mm

1000 mm

B (mm)

Max

510

955

Min

300

745

CDR Boiler

CD Easy-Flue

500 mm

1000 mm

13R/18R

515

960

24R

545

990

13R/18R

305

750

24R

335

780

B Max (mm)

B Min (mm)

Rear

Flue

(B)

*

 With Premier pack

CD C/X/S Boiler

CD Easy-Flue

500 mm

1000 mm

*

500 mm

*

1000 mm

B (mm)

Max

535

980

*

495

*

940

Min

325

770

*

285

*

730

Inside, outside flue sealing collars

Sealing tape

90° bend

Clamp (two screws)

Clamp (three screws)

Flue terminal

supplied fitted

Easy-Flue