background image

                                                                                                                 

TST200 User

s Manual

 

                                                                                                                            5 / 11 

2

2

.

.

0

0

 

 

I

I

n

n

t

t

r

r

o

o

d

d

u

u

c

c

t

t

i

i

o

o

n

n

 

 

a

a

n

n

d

d

 

 

S

S

p

p

e

e

c

c

i

i

f

f

i

i

c

c

a

a

t

t

i

i

o

o

n

n

 

 

 

 

2

2

.

.

1

1

 

 

I

I

n

n

t

t

r

r

o

o

d

d

u

u

c

c

t

t

i

i

o

o

n

n

 

 

 

The TST200 Static  Transfer Switch is a hot pluggable single-phase transfer device, providing 

automatic  switching  between  two  independent  AC  power  sources.  It  could  achieve  very  fast 

switch  without  interrupting  power  and  it  is  suitable  for  important  IT  equipment  which  can  not 

afford power disruption and ATS can not satisfy. Meantime, it integrated a maintenance bypass 

inside  which  could  achieve  automatic  switch  to  maintenance  bypass  (MTS)  incase  of  STS 

maintenance. 

 

 

 

 

 

 

l

 

Hot pluggable 

l

 

Transfer time less than 4ms when input power are synchronization and transfer time is less 

than 10ms in case of input non-synchronization. 

l

 

Integrated Maintenance Bypass 

l

 

Intelligent monitor, diagnostics and alarming 

l

 

Protection and alarm against High Voltage, Low Voltage, Power Failure and Overload. 

l

 

Overload protection: STS shutdown in case of 150% overload and will reconnect after 10s 

l

 

Shortcut  protection:  in  case  of  output  shortcut,  system  would  cutout  output  offering 

protection for input power. 

l

 

User can set up either input as main and the other will be standby automatically 

l

 

Support manual select 

l

 

In  case  of  STS  fail,  the  system  will  choose  one  input  source  as  fix  source,  to  ensure 

uninterruptible power supply 

l

 

RS232 or RS485 communication 

l

 

Structure : 19

2U 

 

 

 

 

 

 

 

 

Summary of Contents for TST200 series

Page 1: ...TST200 User s Manual 1 11 TST200 series Static Transfer Switch USER MANUAL Version 1 0 Date Nov 2009...

Page 2: ...sting and burn in through out the production process Power is certified by TUV in accordance with ISO9001 and can be your reliable power solution provider D Di is sc cl la ai im me er r Unless special...

Page 3: ...de well for later reference The TST200 needs to be installed by professionals and please pay attention to the following points prior to installation 1 Please check the input voltage or voltage of batt...

Page 4: ...o commencing the installation Please follow the local stipulation meantime Any operation against safety requirement or against design manufacture safety standard and are out of the manufacturer warran...

Page 5: ...of STS maintenance l Hot pluggable l Transfer time less than 4ms when input power are synchronization and transfer time is less than 10ms in case of input non synchronization l Integrated Maintenance...

Page 6: ...ion Temp 5C 40C Storage Temp 25C 60C Humidity 93 non condensing Communication RS485 Dry contacts 2 2 3 3 S Sy ys st te em m P Pr ri in nc ci ip pl le e MAIN CNTROL CUR LED DRY CONTACT RS485 CUR K1 3 I...

Page 7: ...e in synchronization Green input 1 normal 2 Input 1 Red input 1 fault 3 Output 1 Green output using input 1 Green Output normal 4 Output Red Output fault 5 Switch switching between input 1 and input 2...

Page 8: ...on fault 1 Dry contact Left 4 Input 2 fault 2 Circuit breaker Input 1 circuit breaker 3 Connector Input 1 L 4 Connector Input 1 N 5 Connector Earth 6 Connector Input 2 L 7 Connector Input 2 N 8 Circui...

Page 9: ...dule and subrack is same to that on outer carton 4 4 2 2 L Lo oc ca at ti io on n Please install the equipment in a location of Dry Clean Cool with good ventilation l Working temperature 0 40 l Storag...

Page 10: ...nd repeat the above action until it is firmly secured 4 4 4 4 2 2 C Co on nn ne ec ct ti in ng g t th he e c ca ab bl le e For the user operation safety cut off the power before installation Connect A...

Page 11: ...e input 1 switch the STS will resume to input 1 At auto position you can not manually choose input 1 or input 2 5 5 4 4 M Ma ai in nt te en na an nc ce e B By yp pa as ss s T Te es st t Plug out the S...

Reviews: